24v backup connection, Ds2100 user's manual (preliminary), 8 24v backup connection – Moog DS2100 User Manual

Page 38

Advertising
background image

DS2100 User's Manual (Preliminary)

SECTION 3: WIRING AND INSTALLATION

PAGE 3-32

3.8 24V Backup Connection

The DS2100 is equipped with a 24V logic supply backup. This backup supply provides logic power to the drive when
AC mains power is removed.

For the

mA size, this backup is mandatory for drive operation.

3.8.1 Size

mA 24V Input Connection

11 12

11 12

Connector J6

mDS

24V Auxiliary

Supply

+24V

GND (0V)

Connector J6

mDS

Fairrite Clamp Core
p/n # 00443164151
(4-Turns of Supply
cable)

Fuse

Figure 3.19 Size

mA 24V DC Input Connection

-

Fixed connector: 12 pins, male connector

-

Mating connector, 12 pins, female, supplied with the drive. Phoenix Combicon (Part # GMSTB 2.5/12-ST-7.62)

-

mA size wiring: cable 14 AWG (2.1 mm

2

).

-

Stripping Length 7mm

-

Tightening torque: 0.5Nm.

Pos.

Name

Function

J6.11

24V

+24V Logic Backup Supply

J6.12

0V

Logic Supply Return (Tied Internally to PE )

Table 3.7 J6 24V Logic Power connector,

mA Size

Advertising