Ds2100 user's manual (preliminary) – Moog DS2100 User Manual

Page 36

Advertising
background image

DS2100 User's Manual (Preliminary)

SECTION 3: WIRING AND INSTALLATION

PAGE 3-30

3.7.1.3 Size

C

EMC Filter,

Fuses etc.

See

Section 2

Installation

3 2 1

L1 L2 L3

Connector J6

C

PE

Stud

a.c. Mains

L1

L2

L3

Protective

Earth

Figure 3.17 Size C AC Mains Input Connection

-

Fixed connector: 5 pins, male connector

-

Mating connector, 5 pins, female, crimped supplied with the drive. (Molex 42816-0512)

-

C size wiring: cable 8 AWG (8.4 mm

2

).

-

PE Stud wiring: cable 6 AWG (13mm

2

)

Pos.

Name

Function

J6.3

L1

Phase "L1", three-phase voltage input 230/460Vac

±10%

J6.2

L2

Phase "L2", ", three-phase voltage input 230/460Vac

±10%

J6.1

L3

Phase "L3", ", three-phase voltage input 230/460Vac

±10%

PE

PE

Protective Earth Stud on Chassis

Table 3.5 J6 AC Mains Power connector, C Size