Echnical data, Configuration, Administration – MGE UPS Systems 66074 User Manual

Page 8: Network, Mib (management information base), Environment sensor, Network management cards, User manual

Advertising
background image

www.mgeups.com

Network
Management Cards

User Manual

T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R

Network Management Card

– User Manual

34003676EN/GA

Page

8/69

1.8 Technical data

1.8.1 Configuration

The user can configure the card with one of the following means:

Z

Web browser

Z

Local serial link

Z

Telnet console

Z

BOOTP/DHCP

Z

Mupgrade

1.8.2 Administration

Z

Up to 50 workstations protected

Z

Up to 15 browsers connected at the same time

Z

E-mail sending configurable according to UPS alarms and transmission of a periodical report

Z

Measurement of temperature and humidity, adjustable thresholds, possibility of sending e-mails and shutting

down the installation

Z

Control of UPS on/off switching via the HTML interface

Z

Adjustment and control of PowerShare outlets via the HTML interface, sequential starting of the installation

and optimisation of backup time by shutting down non-priority systems

Z

Adjustment of date and time via NTP server - Daylight Saving Time management

Z

Protection by encrypted password.

Z

Protection by secured connection SSL and SSH

Z

Saving of logs in the non-volatile memory

Z

Automatic language detection according to browser configuration.

Z

Languages available: English / French / Spanish / German / Italian

Z

On-line help available for each page

Z

Card firmware updated via the network

Z

Card configuration deployment on your installed base through network utility (Mupgrade)

1.8.3 Network

Z

Fast ETHERNET 10/100 Mbits compatibility with auto-negotiation on the RJ45 outlet

Z

SNMP trap port modifiable (by default = 162)

1.8.4 MIB (Management Information Base)

Z

MIB IETF UPS (RFC1628) / MIB MGE V1.7

1.8.5 Environment sensor

Z

Temperature measurement from 0 to 70 °C with +/- 1°C accuracy

Z

Measurement of humidity from 0 to 100 % with +/- 6 % accuracy

Z

Min / max time-stamped function for temperature and humidity

Z

Choice of temperature readings in Celsius or Fahrenheit

Z

High and low thresholds, hysteresis and offset adjustable via Web interface

Z

Possibility of notification of status changes by e-mail, SMS or SNMP traps

Z

Position detection of 2 dry contacts (maximum sensor/contact distance: 20 m)

Z

Name and status of each configurable contact

Advertising
This manual is related to the following products: