Clearances, Warning, Clearances to combustibles mantel clearances – Monessen Hearth Direct Vent Gas Fireplace MDV500 User Manual

Page 11: Figure 7 - mantel clearances

Advertising
background image

75D2523

11

CLEARANCES

CLEARANCES TO COMBUSTIBLES

MANTEL CLEARANCES

NOTE: The combustible area around the fireplace must
not protrude more than

1

/

2

" from the facing. If it does, it is

considered a mantel and must meet the mantel requirements
listed in this manual.

Figure 6 - Clearances from the Mantel,

Ceiling, and Side Wall

WARNING

Follow these instructions carefully to ensure safe installation. Failure to follow
in struc tions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material
other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall
be installed on a metal, wood or noncombustible material panel ex tend ing full width
and depth of the appliance.

Figure 7 - Mantel Clearances

10

3

/

4

"

9

1

/

2

"

8

1

/

4

" 7"

12"

6"

12"

10"

8"

6"

4"

2

1

/

2

"

Wall

Insulation

Board

Stud

Side View

Top View

Combustible mantle

Side wall

12" minimum

6" minimum from

both side walls

72" minimum

12"

maximum

FIREPLACE

HOOD

WALL

COMBUSTIBLE

MATERIAL

AREA

6"

5"

3"

2.5"

4.5"

45°

3.5"

3.5"

1"

1.5"

1.5"

Advertising