ELECTRONIC IGNITION

TROUBLESHOOTING

START

1. Turn gas supply off.
2. Turn ON/OFF switch to “ON”
Power to module (24V Normal)

YES

Is there a spark across

ignitor sensor gap?

YES

Turn on gas.

Does pilot burner light?

YES

Does spark stop when pilot is lit?

YES

Does main burner light?

YES

Does system run until ON/OFF switch

is in “OFF” position?

YES

END OF TROUBLESHOOTING

Check: Line voltage (120VAC)

Low voltage transformer (19.5 minimum VAC)

ON/OFF

switch

Wiring

connections

Unplug ignition lead and
check spark at module

(24VAC

normal).

Is spark OK?

NO Replace

module

YES

A. Check ignition cable ground wiring, ceramic insulator and gap.

Correct if necessary.

B. Does ignition cable show signs of melting or buckling?

Take protective action to shield cable and boot from
excessive temperatures.

A. Are all manual gas valves open?
Are supply tubing and pressure good?
Are pilot burner orifices blocked?
B. Check electrical connections between module and pilot

operator on gas control.

C. Check for 24VAC across PV-MVPV terminals.
If voltage is correct, replace gas control.
If voltage is not correct, replace module.

NOTE: If module goes into lockout, reset system.
A. Check continuity of ignition cable and ground wire.
B. Clean flame rod.
C. Check electrical connections between flame rod and module.
D. Is ceramic flame rod insulator cracked?
E. Is pilot flame a steady blue? Does flame cover flame rod?
If not, adjust pilot flame. Replace module if problem persists.

A. Check for 24VAC across MV-MVPV terminal.
Replace module if there is no voltage.
B. Are electrical connections between module and gas

control good?
If connections are good, replace gas control or gas
control operator.

NOTE: If module goes into lockout, reset system.
A. Check continuity of ignition cable and ground wire.
NOTE: If ground is poor or erratic, shutdown may

occasionally occur even though operation is normal at
time of checkout.

B. Is pilot flame a steady blue? Does flame cover flame rod?
If above checks out, replace module.

NO

NO

NO

NO

NO

NO