Electrical installation, Warning, Optional dc remote systems – Monessen Hearth Direct Vent Gas Fireplace MDV500 User Manual

Page 32

Advertising
background image

32

75D2523

#1

#2

#3

#4

#5

#6

7#

Electronic Valve

GRAY #7

RED #2

RED #2

BLACK #4

GREEN #6

BLUE #1

BLUE

YELLOW

YELLOW

WHITE #3

MAGENTA #5

15’ Wall Switch Wire

BLACK

WHITE

Switch

RS

OFF

ON

Transformer

Secondary

24V

WHITE

WHITE

GREEN

BLACK

BLACK

Primary - 120V

To Junction Box

Pilot Assembly

Spark
Sense

Ignition Module (Synetek)

HI

LO

EV1

EV2

ELECTRICAL INSTALLATION

ELECTRONIC PILOT IGNITION WIRING

REMOTE WALL SWITCH

Position the wall switch. Do not extend beyond the 15 feet of wire.

OPTIONAL DC REMOTE SYSTEMS

These instructions replace the section entitled Hearth Mount in the Millivolt hand held remote instructions supplied with
the remote.
1. Follow instructions on remote control to snap remote cover plate to remote receiver.
2. Connect the wire terminal from the remote receiver. This replaces the 15' wall switch connection to the switch. See

Figure 41.

3. Use screws that came with remote control to mount remote control receiver at junction box (for your wall switch) or at

control panel (when installation in unit is preferred).

Figure 41 - Electronic Ignition System Wiring Diagram

WARNING

Do not connect 110-120 VAC to the
Remote Wall Switch. The appliance
will malfunction.