Vent installation – Monessen Hearth Direct Vent Gas Fireplace MDV500 User Manual

Page 25

Advertising
background image

75D2523

25

Figure 32 - Maximum elbow Usage

• Up to two 45° elbows may be used within the

horizontal run. For each 45° elbow used on the
horizontal plane, the maximum horizontal length
must be reduced by 18" (450mm).

Example: Maximum horizontal length

No elbows = 10’ (3m)

1x45° elbows = 8.5’ (2.6m)

2x45° elbows = 7’ (2.1m)

• A minimum of an 8' (2.5m) vertical rise is

required.

• Two sets of 45°elbows offsets may be used within

the vertical sections. From 0 to a maximum of 8'
(2.5 m) of vent pipe can be used between elbows.
See Figure 32.

• Determine the roof pitch and use the appropriate

starter kit for offset installation.

• The maximum angular variation allowed in the

system is 270°. See Figure 32.

• The minimum height of the vent above the high-

est point of penetration through the roof is 1'
(305mm).

1

2

3

4

1

2

3

4

Example:

Elbow 1 = 90°

Elbow 2 = 45°

Elbow 3 = 45°

Elbow 4 = 90°

Total Angular Variation = 270°

Figure 31 - Support Straps for Horizontal Runs

40' Maximum Height

8' Minimum Height

40' Maximum Height

8' Minimum Height

10'

Maximum

10'

Maximum

Support Straps

Every 3'

Support Straps

Every 3'

Support

Straps

Every

5'Vertical

This Gas Fireplace has been approved for,
• Vertical installations up to 40' (12m) in height. Up to a 10' (3m)

horizontal vent run can be installed within the vent system
using a maximum of two 90° elbows. See Figure 31.

VENT INSTALLATION

VERTICAL THROUGH-THE-ROOF APPLICATIONS (continued)

Advertising