Electrical installation, Warning, Caution – Monessen Hearth Direct Vent Gas Fireplace MDV500 User Manual

Page 31: Electrical wiring, Do not connect wall switch to ac (110v) circuit

Advertising
background image

75D2523

31

ON

OFF

OPTIONAL REMOTE

RECEIVER

ON

OFF

RS

PILOT

HI

LO

ON

OFF

TH

TP

TH/TP

ON

OFF

OPTIONAL WALL

SWITCH

GRA

Y

BLUE

BLACK

BLACK

BLACK

BL

UE

WHITE

RS

REMOTE WALL MOUNTED SWITCH (FOR MILLIVOLT VALVES ONLY)

A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in
a junction box at the desired location on the wall. See Figure 40. Do not extend beyond the wall switch wire length pro-
vided.

NOTE: Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire
is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code.

Figure 40 - Wiring Diagram for Wall Switch

(Millivolt Units Only)

ELECTRICAL INSTALLATION

ELECTRICAL WIRING

Verify proper operation after servicing.

This fireplace will work without any electrical supply except to operate blower and electronic ignition system.
NOTE: If installed in mobile home, fireplace must be bolted securely to floor.

WARNING

Electrical connections should only be performed by a qualified, licensed electrician.
Main power must be off when connecting to main electrical power supply or performing
service. All wiring shall be in compliance with all local, city, and state codes. The
appliance, when installed, must be electrically grounded in accordance with local
codes, or in the absence of local codes, with the National Electrical Code ANSI/ NFPA
70 (latest edition) and Canadian Electrical Code, CSA C22.1.

CAUTION

Label all wires before disconnecting when servicing controls. Wiring errors can cause
improper and dangerous operation.

WARNING

Do not connect
wall switch to AC
(110V) circuit.