Pre-installation information – Monessen Hearth Direct Vent Gas Fireplace MDV500 User Manual

Page 6

Advertising
background image

6

75D2523

PRE-INSTALLATION INFORMATION

INSTALLING ABOVE 2000 FEET

• In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elevations.
• In Canada, these appliances are certified for altitudes of 0 – 2000 ft, and must be de-rated by 10 percent for installations

between 2000 and 4,500 ft. (derate an additional 4% for every 1,000 ft. above 4,500 ft. elevations).

If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with local
gas utility.
If installing this appliance at an elevation above 4,500 feet (in Canada), check with local authorities.

ORIFICE SIZES, PRESSURES AND BTUs

NATURAL GAS

PROPANE GAS

Manifold Press: (W.C.)

3.5"

Manifold Press: (W.C.)

10"

Maximum Supply Pressure

10.5"

Maximum Supply Pressure

13"

Minimum Supply Pressure

4"

Minimum Supply Pressure

11"

BEFORE YOU START

Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and
immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts.
Check your packing list to verify that all listed parts have been received. You should have the following:

• Fireplace (Firebox and Burner System)

• Fasteners

• Front Floor Brick Assembly

• White Toggle Switch

• Rock Wool

• Non-Combustible Panel

• Log Set

• Switch Cover Plate

• Canopy

• Restrictor Plate/Disc (2 each)

ITEMS REQUIRED FOR INSTALLATION
Tools: Building

Supplies:

• Phillips Screwdriver

• Framing Materials

• Hammer

• Wall Finishing Materials

• Saw and/or saber saw

• Caulking Material (Noncombustible)

• Level

• Fireplace Surround Material (Noncombustible)

• Measuring Tape

• Piping Complying with Local Codes

• Electric Drill and Bits

• Tee Joint

• Pliers

• Pipe Sealant Approved for use with Propane/LPG

• Square

(Resistant to Sulfur Compounds)

• Pipe

Wrench

Model Number

MDV500

MDV600

Natural

Propane

Natural

Propane

Max. Btu/hr Input

30,000

30,000

32,000

32,000

Min. Btu/hr Input

21,500

23,500

22,000

26,000

Burner Orifice size (as shipped)

7/64"

#51

#34

#50

Advertising