Lighting pilot for the first time - millivolt, Lighting pilot - millivolt, Pilo t – Monessen Hearth Direct Vent Gas Fireplace MDV500 User Manual

Page 39: Operating instructions - millivolt, Warning, Danger

Advertising
background image

75D2523

39

PILO

T

OF

F

PI

LO

T

ON

Continued on next page

OPERATING INSTRUCTIONS - MILLIVOLT

APPROVED LEAK TESTING METHOD
You may check for gas leaks with the following methods only:
• Soap and water solution
• An approved leak testing spray
• Electronic sniffer

NOTE: Remove any excessive pipe
compound from the connections.
Excessive pipe compound can set off
electronic sniffers.

1. Depress and turn knob counterclockwise

to pilot position.

2. Depress fully and hold pilot gas knob. Depress piezo

ignitor as many times as needed to ignite the pilot.
Keep knob fully depressed for a few seconds.
Release and check that pilot continues to burn.

If the pilot does not stay lit, repeat steps 1 and 2.

Figure 54 - Pilot Position

Check for gas leaks in each of the following locations:
• Pipe from the gas supply line connection to the gas valve
• Burner connections

• Field made joints / gas shutoff valve

• Pilot

• Factory made joints

• Each joint or connection

• All joints on valve and control body

LIGHTING PILOT FOR THE FIRST TIME - MILLIVOLT

WARNING

If using a soap and water
solution to test for leaks,
DO NOT spray solution
onto control body.

DANGER

Never check for gas leak with open flame!

LIGHTING PILOT - MILLIVOLT

Advertising