Vent installation, Warning, Notice – Monessen Hearth Direct Vent Gas Fireplace MDV500 User Manual

Page 19

Advertising
background image

75D2523

19

HOT

HOT

VENT INSTALLATION

4. Apply a bead of non-hardening mastic around the outside

edge of vent cap. Position the vent cap in the center of hole
on the exterior wall with the word “UP” on the vent cap
facing up. Insure proper clearance of 1" to combustibles
is maintained. Attach the vent cap with four wood screws
supplied. See Figure 18.

WARNING

Do not recess vent termination
into any wall. This will cause a
fire hazard.

NOTE: Replace the wood screws with appropriate
fasteners for stucco, brick, concrete, or other types
of siding.

For vinyl siding, stucco, or wood exterior use vinyl siding
standoffs between vent cap and exterior wall for Simpson or
Selkirk Terminations only. The vinyl siding standoff prevents
excessive heat from melting the vinyl siding material. N

OTE

:

Monessen Termination does not require standoff. Bolt the
vent cap to the standoff or wall. Apply non-hardening mastic
around outside edge of the standoff instead of the vent cap
assembly. Use wood screws provided to attach the standoff.
See Figure 19.
5. Slide the wall thimble over the vent pipe before connecting

the horizontal run to the vent cap. See Figure 20.

6. Carefully move the fireplace with vent assembly attached

toward the wall and insert the vent pipe into the horizontal
termination. The pipe overlap should be a minimum of
1

1

/

4

". Apply silicone to the outer pipe connection. Fasten

all vent connections with screws provided.

7. Slide the wall thimble against the interior wall surface and

attach with screws. See Figure 20 .

NOTICE

For more information, follow
instructions that comes with
terminations.

Figure 18 - Installing Horizontal Vent Cap

REAR WALL VENT INSTALLATION (continued)

Figure 19 - Installing Vinyl Siding Standoff

and Termination

Vent Cap

Wood

Screw

Apply Mastic to

All Four Sides

Figure 20 - Connecting Vent Cap with Horizontal Vent Pipe

Interior Wall

Surface

Fire Stop

Assembly

Horizontal

Vent Pipe

Screw

Vent Cap

(Horizontal

Termination)

Apply

Mastic to

All Four

Sides

Cut Vinyl Siding Away to Fit

Standoff or Termination

Wood Screw

Termination

Bolt

Nut

Standoff #1250 or

5DT-VS

(Not Required

for Monessen

Termination)

Advertising