7. The program will load the file and then ask if it should upload boot code. Press

“N” to continue unless otherwise directed by the release notes or an Intel support
professional.


8. The program next asks if it should upload operational code. Press “Y” to

continue. The process of uploading operational code takes a few minutes.


9. Once the operational code updates and verifies, press any key to continue. Then

press <ESC> to exit the program.


10. Shut the system down and remove any diskettes in the system.

11. Disconnect the AC power cord from the system and wait 60 seconds.

12. Reconnect the AC power cord and power up the system.

FRU/SDR Load Utility Description

The Field Replacement Unit (FRU) and Sensor Data Record (SDR) load utility is a
DOS-based program used to update the server management subsystem’s product
level FRU and SDR non-volatile storage components (EEPROMs). The utility:

Discovers the product configuration based on instructions in a master

configuration file

Displays the FRU information

Updates the EEPROM associated with the Baseboard Management

Controller (BMC) that holds the SDR and FRU area

Generically handles FRU devices that might not be associated with the BMC

What You Need to Do


Either run the utility directly from the Resource CD or from diskettes created
from the CD.

If you run the FRU/SDR Load Utility from a diskette, copy the utility from the CD.
Follow the instructions in the included README.TXT file.

If the diskette drive is disabled, or improperly configured, use BIOS Setup to enable
it. If necessary, disable the drive after you are done with the FRU/SDR utility.

How You Use the FRU/SDR Load Utility


The utility: