Server Board Jumpers

Figure 49: Server Board Jumpers


Table 40: Configuration Jumper

Jumper
Name

Pins

What it does at system reset

BMC WP

A

BMC boot block is write protected (normal operation). If these pins are not
jumpered, BMC boot block is erasable and programmable at next reset.

CMOS CLR

B

If these pins are jumpered, the CMOS settings are cleared. These pins should
not be jumpered for normal operation.

PSWD CLR

C

If these pins are jumpered, the CMOS password is cleared. These pins
should not be jumpered for normal operation.

RCVRY
BOOT

D

If these pins are jumpered, the system will attempt BIOS recovery. These pins
should not be jumpered for normal operation.

Diagnostic LEDs


To help diagnose POST failures, a set of four bi-colour diagnostic LEDs is located on
the back edge of the baseboard. Each of the four LEDs can have one of four states:
Off, Green, Red, or Amber.

The LED diagnostics feature consists of a hardware decoder and four dual colour
LEDs. During POST, the LEDs will display all normal Port80 codes representing the
progress of the BIOS POST. Each postcode will be represented by a combination of
colours from the 4 LEDs. The LEDs are in pairs of green and red. The post codes
are broken into two nibbles, an upper and a lower nibble. Each bit in the upper