Mechanical specifications, Setup parameters – Intelligent Motion Systems MForce PowerDrive Plus MForce Series Microstepping PowerDrive User Manual

Page 14

Advertising
background image

1-8

Microstepping MForce PowerDrive Manual Revision R040507

Mechanical Specifications -

Dimensions in Inches (mm)

Figure 1.2.1: MForce PowerDrive Mechanical Specifications

Microstepping MForce PowerDrive Setup Parameters

Name

Function

Range

Units

Default

MHC

Motor Hold Current

0 to 100

percent

5

MRC

Motor Run Current

1 to 100

percent

25

MSEL

Microstep Resolution

1, 2, 4, 5, 8, 10, 16, 25, 32, 50,

64, 100,108, 125, 127,128,

180, 200, 250, 256

µsteps per

full step

256

DIR

Motor Direction Override

0/1

CW

HCDT

Hold Current Delay Time

0 or 2-65535

mSec

500

CLK TYPE

Clock Type

Step/Dir. Quadrature, Up/Down

Step/Dir

CLK IOF

Clock and Direction Filter

50 nS to 12.9 µS

(10 MHz to 38.8kHz)

nS (MHz)

200nS(2.5

MHz)

USER ID

User ID

Customizable

1-3 characters

IMS

WARN TEMP

Warning Temperature

0 to +125

ºC

80

EN ACT

Enable Active High/Low

High or Low

High

Table 1.2.6: Setup Parameters

Setup Parameters

The following table illustrates the setup parameters. These are easily configured using the IMS SPI Motor Interface
configuration utility. An optional Parameter Setup Cable is available and recommended with the first order.

3.473

(88.21)

2X 0.580

(2X 14.73)

Ш 0.187 ±0.01

(Ш 4.75 ±0.25)

2X #8 Screws

for End Mount

3.00 ±0.01

(76.2 ±0.25)

2.116

(53.75)

0.225

(5.72)

P4

P3

P1

3.473

(88.21)

Ø 0.160 ±0.01 Thru

(Ø 4.06 ±0.25 Thru)

4X #6 Screws

for Flat Mount

0.308 TYP.

(7.82 TYP.)

2.931 TYP.

(74.45 TYP.)

3.897

(98.98)

0.417 TYP.

(10.59 TYP.)

0.160 ±0.01

(4.06 ±0.25)

2.950

(74.93)

Advertising