1-9

Part 1: Hardware Specifications

Pin Assignment and Description

P1 12-Pin Locking Wire Crimp Connector Option - Power, I/O and SPI

Communications

Pin Assignment - P1 Power, I/O and SPI

Connections

Pin #

Function

Description

Pin 1

N/C

No Connect

Pin 2

N/C

No Connect

Pin 3

Opto Reference

The Signal applied to the Optocoupler Reference will

determine the sinking/ or sourcing configuration of the inputs.

To set the inputs for sinking operation, a +5 to +24 VDC

supply is connected. If sourcing, the Reference is connected

to Ground.

Pin 4

Step Clock/Channel

A/ Clock Up

Step Clock input. The step clock input will receive the clock

pulses which will step the motor 1 step for each pulse. It

may also receive quadrature and clock up type inputs if so

configured.

Pin 5

Enable

Enable/Disable Input will enable or disable the driver output

to the motor. In the disconnected state the driver outputs are

enabled in either sinking or sourcing configuration.

Pin 6

Direction/Channel B/

Clock Down

Direction input. The axis direction will be with respect to the

state of the Direction Override Parameter. It may also receive

quadrature and clock up type inputs if so configured.

Pin 7

+5 VDC Output

Supply voltage for the MD-CC300-000 Cable ONLY!

Pin 8

SPI Clock

The Clock is driven by the SPI Master. The clock cycles once

for each data bit.

Pin 9

GND

Communications Ground.

Pin 10

MISO

Master-In/Slave-Out. Carries output data from the MFM back

to the SPI Master.

Pin 11

CS

SPI Chip Select. This signal is used to turn communications

on multiple MFM units on or off.

Pin 12

MOSI

Master-Out/Slave-In. Carries output data from the SPI Master

to the MFM.

Table 1.2.7: P1 Connector – Power, I/O and SPI Communications

NEED A CABLE?

The following cables

and converters are

available to interface

with P1:

12-Pin Locking Wire Crimp

PD12-1434-FL3

P3

P1

1 3 5 7 9 11
2 4 6 8 10 12

NEED A CABLE?

The following cables

and converters are

available to interface

communications with

USB to SPI:

MD-C300-000

10-Pin IDC to 12-Pin Locking

Wire Crimp Adapter

All SPI Communications will

connect to the P1 Connector.

An adapter is available to interface

the MD-CC300-000 to the 12-Pin

Locking Wire Crimp connector.

MD-ADP-1723C

This adapter may be used in

conjunction with the following

Prototype Development cables to

interface power and logic:

PD12-1434-FL3 (10')

ADP-3512-FL (12")

See Appendix A for details.

Figure 1.2.2: P1 — 12-Pin Locking Wire Crimp Pin Configuration

Recommended Connector Shell and Pins

Shell: AMP P/N 1-794617-2
Pins: 12 x AMP P/N 794610-1
Wire: 22 AWG Shielded Twisted Pair