9

Part 2: Interfacing and Configuring

P3

Unregulated

Linear or

Switching

Power Supply

Power

Ground

+VDC

Shield to

Earth Ground

+

!

WARNING! Do not connect

or disconnect cabling while

power is applied!

Optional Prototype

Development Cable:

PD02-3400-FL3

Pin 1

Pin 2

Basic DC Power Connection

Figure 2.2.2: MForce PowerDrive DC Power Connection

Recommended Power and Cable Configurations

Cable length, wire gauge and power conditioning devices play a major role in the performance of your MForce
PoweDrive.

Example A demonstrates the recommended cable configuration for DC power supply cabling under 50 feet long.
If cabling of 50 feet or longer is required, the additional length may be gained by adding an AC power supply
cable (see Examples B & C).

Correct AWG wire size is determined by the current requirement plus cable length. Please see Table 2.2.1 for
recommended wire gauges.

Example A: DC Power Cabling Under 50 Feet

Shield to Earth Ground

on Supply End Only

DC Voltage from

Power Supply

500 µf

Per Amp

+

-

Ferrite

Beads

P

Type RFI Filter

r Required Current

+

-

Shielded Twisted Pair

Cable Length

less than 50 Feet

P3:2
P3:1

Figure 2.2.3: DC Cabling - Under 50 Feet