Intelligent Motion Systems MForce PowerDrive Plus MForce Series Microstepping PowerDrive User Manual

Page 48

Advertising
background image

30

Microstepping MForce PowerDrive Manual Revision R040507

IMS SPI Motor Interface Menu Options

File

> Open: Opens a saved *.mot (Motor Settings) file.
>

Save: Saves the current motor settings as a *.mot file for later re-use

>

Save As

>

Exit - Disconnects from the device and opens the Initialization Dialog.

View

> Motion Settings: Displays the Motion Settings screen
>

IO Settings: Displays the IO Settings Screen

>

Part and Serial Number: Displays the part and serial number

Red: Out of Range Value.

The Set Button will disable

as the the Motor Interface will

not allow an out of range value

to be stored.

Blue: New Value which has not yet

been set to NVM.

Black: This is the value

Currently Stored in NVM

Figure 2.6.1: SPI Motor Interface Color Coding

Perform File

Operation

Open Motor Settings

File (*.mot)

Save Motor Settings

Save Motor Settings As

Exit the Motor Interface

Figure 2.6.2: SPI Motor Interface File Menu

View Settings

Screen

Motion Settings Screen

I/O Settings Screen

Read-Only Part

and Serial Number Screen

Figure 2.6.3: SPI Motor Interface View Menu