Intelligent Motion Systems MForce PowerDrive Plus MForce Series Microstepping PowerDrive User Manual

Page 22

Advertising
background image

4

Microstepping MForce PowerDrive Manual Revision R040507

Figure 2.1.2: End Mounting the MForce PowerDrive

Securing Power Leads and Logic Leads

Some applications may require that the MForce and/or the connected motor to move with the axis motion. If this
is a requirement of your application, the motor leads must be properly anchored. This will prevent flexing and
tugging which can cause damage at critical connection points on the MForce connectors.

Layout and Interface Guidelines

Logic level cables must not run parallel to power cables. Power cables will introduce noise into the logic level
cables and make your system unreliable.

Logic level cables must be shielded to reduce the chance of EMI induced noise. The shield needs to be grounded at
the signal source to earth. The other end of the shield must not be tied to anything, but allowed to float. This allows
the shield to act as a drain.

Power supply leads to the MForce PowerDrive need to be twisted. If more than one driver is to be connected to
the same power supply, run separate power and ground leads from the supply to each driver.

2 x #8-32 Screw

2 x #8 Split Lockwasher

2 x #8 Flat Washer

Mounting Hardware

2 x M4 - 0.70 Screw

2 x M4 Split Lockwasher

2 x M4 Flat Washer

Mounting Hardware (Metric)

Mounting Surface

3.000 TYP

(76.20 TYP)

Use #29 Drill Size (3.3 mm)

Tap to #8-32 2 PL (M4 - 0.70)

Mounting Hole Pattern

Recommended Tightening Torque:

8 - 9 lb-in (89.6 - 100.8 N-cm)

NOTE: Ensure that

proper clearance is

allowed for wiring

and cabling.

Especially when end

mounting the device.

NOTE: Mounting

Hardware is not

supplied.