Warning High – The sensor reading indicates a problem with the device. This
could become a critical problem if action is not taken. Run diagnostics on
sysplanar0 to determine what repair action is needed.

Warning Low – The sensor reading indicates a problem with the device. This
could become a critical problem if action is not taken. Run diagnostics on
sysplanar0 to determine what repair action is needed.

Hardware Error - The sensor could not be read because of a hardware error.
Run diagnostics on sysplanar0 in problem-determination mode to determine what
repair action is needed.

Hardware Busy – The system has repeatedly returned a busy indication, and a
reading is not available. Try the service aid again. If the problem continues, run
diagnostics on sysplanar0 in problem-determination mode to determine what
repair action is needed.

This service aid can also be run as a command. You can use the command to list
the sensors and their values in a text format, list the sensors and their values in
numerical format, or a specific sensor can be queried to return either the sensor
status or sensor value.

Run the command by entering one of the following:

/usr/lpp/diagnostics/bin/uesensor -l | -a
/usr/lpp/diagnostics/bin/uesensor -t

token

-i

index

[-v]

Flag

Description

-l

List the sensors and their values in a text format.

-a

List the sensors and their values in a numerical format. For each sensor,
the following numerical values are displayed as:
token index status measured value location code

-t token

Specifies the sensor token to query.

-i index

Specifies the sensor index to query.

-v

Indicates to return the sensor measured value. The sensor status is
returned by default.

126

RS/6000 Enterprise Server Model H80 Series User's Guide