Step 3. running system verification, Step 4. additional system verification – IBM Enterprise Server H80 Series User Manual

Page 169

Advertising
background image

Step 3. Running System Verification

On the Diagnostic Operating Instructions screen, do the following:

1. Press Enter.

2. If the terminal type has not been defined, you must use the Initialize Terminal

option on the Function Selection menu to initialize the operating system
environment before you can continue with the diagnostics.

3. If you want to do a general checkout with minimal operator action, select the

Diagnostic Routines option on the Function Selection menu.

If you want to do a more complete checkout including the use of wrap plugs,
select the Advanced Diagnostics option on the Function Selection menu. The
advanced diagnostics are primarily for the service representative; they may
instruct you to install wrap plugs to better isolate a problem.

4. Select the System Verification option on the Diagnostic Mode Selection menu.

5. If you want to run a general checkout of all installed resources, Select the All

Resource option on the Diagnostic Selection menu.

If you want to check one particular resource, select that resource on the
Diagnostic Selection menu.

6. Go to Step 4.

Step 4. Additional System Verification

The checkout programs end with either the Testing Complete menu and a message
stating

No trouble was found

or the A Problem Was Detected On (Time Stamp)

menu with a service request number (SRN).

1. Press Enter to return to the Diagnostic Mode Selection menu.

2. If you want to check other resources, select the resource. When you have

checked all of the resources you need to check, go to Step 5.

Chapter 7. Using the System Verification Procedure

153

Advertising