SECTION 5—CENTER MOUNT FOOTRESTS

Adjustable ASBA Seat

20

Part No 1143238

Chairs built after 12/01/2008

ƽ WARNING

While the wheelchair is moving, minimum ground clearance for the front rigging is
three inches. If the wheelchair is not moving, the front rigging MUST maintain a
minimum of one inch ground clearance - otherwise personal injury and damage may
result.

NOTE: For this procedure, refer to FIGURE 5.3.

1. Remove the two mounting screws that secure the button head cleat to the extension 

housing.

2. Adjust the footrest extension tube to the desired height.

3. Secure the extension tube to the desired height with the button head cleat and 

mounting screws. Securely tighten.

4. Repeat STEPS 1‐3 for the other extension tube.

FIGURE 5.3 Adjusting the Height of the Manual Center Mount Footrest -

Chairs built after 12/01/2008

Extension

Housing

Extension Tube

Mounting Screws

Extension Tube Mounting Holes

Button Head Cleat