22

M

H

F

S

CONDITION

CTL

P.READ

AUTO OFF

V.VAR

REMOTE

PB/EE

16:9

TC UB DF SERVO

GEN

CF

AP

525
625

2-4 COUNTER DISPLAY

2 CONTROLS, CONNECTORS AND DISPLAYS

Indicator section

[VCON] button

* During swap editing, player information is shown only by the

indicators in the section when the player is selected. The [AUTO
OFF] indicator always shows recorder information.

Indication

Meaning when lit

CTL

The CTL counter is shown.

TC

The time code is shown.

UB

The user bits are shown.

DF

The CTL counter or time code is in the
drop-frame mode. (525)

SERVO

Servo is stable.

CF

The color frame servo is set. This
indication lights during recording. When
the [CF] switch is ON and a tape with color
frame information is played back, this
indication also lights.
When the PLAYER is selected during
SWAP editing, the [CF] indication does not
light.

GEN

Signals are input to the [REF] connector.

(Blinking) GEN

The input digital audio signals cannot be
recorded correctly because no external
sync signal is input.

16:9

Wide aspect ID signal is being played back.

AP

A non-D-9 tape is played back.

AUTO OFF

A malfunction or abnormality has occurred.

P. READ

The VCR is in the Pre-read mode.

V. VAR

The video parameters can be adjusted.

PB/EE

The PB/EE Auto Switching mode is
selected.

PB

The PB mode is selected.

REMOTE

The VCR is in the Remote mode.

CONDITION

Channel condition is normal.

Minor errors.
Major errors. Normal playback is not
possible.

(Blinking)

Tracking is not correct.

Video signal system

4

525

The NTSC signal system is set.

4

625

The PAL signal system is set.

The video signal system can be set with menu switch No. D95
<525/625> (on the top menu). After selecting the video signal
system, turn this unit OFF then ON again to switch to the
selected video signal system.

The following error messages may be
displayed during swap editing.

Indication

Meaning

Local

The player’s Local/
Remote is set to “Local”.

No Tape

No cassette is loaded in
the VCR.

Bump Error

Bump error occurs.

No Edit Cmd The edit mode is not

selected.

Dur = 0

Duration is set to 0.

Servo Error

Servo error occurs.

Split No A.

The audio insert mode is
not selected.

Rec Inh

Recording is not possible
on this cassette.

IN/OUT Rev

The IN and OUT points
are reversed in terms of
the timeline.

Over 300%

Tape speed is more than
3x.

Over -200%

Reverse tape speed is
more than -2x.

VTR No Play The VCR will not

function.During editing,
the VCR stops.

AuCondition

Editing was interrupted
because of audio
conditions deteriorated.

NO CTL

Stops the operation when
insert editing is executed
in a non-recorded
section.

Press the [STOP] button to release
error display indications.

“No Tape” indication goes out when a
cassette tape is loaded.

Video/audio control display

* For adjustment of each item, refer to

“Video control adjustment” on page 118.

23

E

Ⅵ Ⅵ Ⅵ Ⅵ F

Remaining time of 15 minutes or more

E

Ⅵ Ⅵ Ⅵ

Remaining time of less than 15 minutes

E

Ⅵ Ⅵ

Remaining time of less than10 minutes

E

Remaining time of less than 5 minutes

E

(blinking)

Remaining time of less than 2 minutes

E

(blinking)

Remaining time of less than 1 minutes

No indication

The remaining time is being calculated.

PLAY

R: TCR 00:00:00:01

STOP

TCR 00:00:00:00

SUB TCR 00:00:00:00

2 CONTROLS, CONNECTORS AND DISPLAYS

2-5 ON-SCREEN DISPLAY

1. Tape counter display, etc.

Menu switch No. 504 <INFORMATION SELECT>

SUB read-out mode

TC read-out mode

Counter mode

Operation mode

Sub time code

Counter

F
F
F
F
F

On-screen display

On-screen information is available only via the rear
panel [LINE 2 - SUPER OUT] connector.

1. Tape counter display

● Shows data when the [ON SCREEN] switch on

the sub panel is set to ON.

● You can choose what information is shown with

menu switch No. 504 <INFORMATION
SELECT>.
Only time data is displayed when “TIME (0)” is
selected.
Both time data and VCR operation mode are
displayed when “TIME & MODE (1)” is selected.

● The display position can be shifted horizontally

with menu switch No. 501 <CHARA
H.POSITION> and vertically with No. 502
<CHARA V.POSITION>.

● Set the [ON SCREEN] switch on the sub panel

to OFF to turn off the on-screen display.
* If menu switch No. 513 <EDIT ON SCREEN>

is set to “ON”, you cannot turn the on-screen
display off.

● When menu switch No. 504 <INFORMATION

SELECT> is set to “TIME + SUB TC” or “TIME +
SUB TC + MODE”, sub time code information is
shown simultaneously on a different line.

2. Menu switch setting display

Press the [MENU] button to call up the menu
setting display on screen.
● Select a menu item by turning the jog dial. For

details, refer to “Menu switch setting” on
page 31.

● Pressing the [MENU] button restores the normal

display.

3. Hour meter data display

Hour meter data can be displayed in the Menu
Switch Setting mode. For details, refer to “Hour
meter data display” on page 39.

4. Warning code display

If a malfunction occurs, the corresponding warning
code is automatically displayed.
For details, refer to “Warnings with Indicators” on
page 145.

5. Tape remaining time display

When menu switch No. 505 <REMAIN ENABLE>
is set to “ENABLE(1)”, tape remaining time is
shown in 6 steps.

Player/recorder
indication

2. Menu setting display

0002

DH:DRUM HOUR METER

3. Hour meter data display

4. Warning display

5. Tape remaining time display

WARNING 02 1

CONDENSATION ON DRUM

PLAY

CTL

0:00:00:00

E

F

008:CAP LOCK(525)

SW SEL

002:OPERATION LOCK

OFF

003:SYNC SELECT

AUTO

005:AUTO TRACKING

ON

009:CAP RE-LOCKING DIR.

ACCELERATION

* Shown when the tape speed is less than ±0.3x.

Player/recorder indication

When the editing screen display is not shown during swap editing,
this indicates which VCR's data is currently displayed on the tape
counter.
P:When the player is selected (SUBTC is not shown)
R:When the recorder or both the recorder and player are selected.

Counter mode

CTL

: CTL data

TCR : Time code reader data
TC1

: Time code reader data (when the first field is played back)*

TC2

: Time code reader data (when the second field is played

back)*

TCR• : CTL interpolation mode
TCG : Time code generator data
UBR : User bits reader data
UBG : User bits generator data
LTC

: LTC data

Drop-frame display (NTSC only)
In recording or playback in the Drop-frame
mode, the counter display is as shown below.

TCR 00:00:00·00

Drop frame indication

Advertising