Select the audio to be output to the headphones jack or the rear panel [AUDIO MONITOR L/R] connectors. Select
a single channel or mixed audio from the four available channels. During playback, select the playback audio monitor
output signal.

1. Press the [AUDIO MONITOR] button so that the [AUDIO MONITOR] button

is illuminated.

● When the [AUDIO MONITOR] button is illuminated, the audio channel

indicator can be used for the audio monitor output signal.

2. Select the audio monitor output signal by pressing the audio signal select

button.

Select the audio signal from CH 1 to CH 4 to be output to the L and R channels
of the [AUDIO MONITOR] connectors and the headphones jack.

The selected channel indicator lights.

[AUDIO MONITOR]
button

L channel

R channel

Channel indicators

Audio signal select buttons

AUDIO

MONITOR

● Select the output level

mode for audio monitor
mixing output with menu
switch No. 222 <MONITOR
MIX MODE>.

● Setting the audio monitor

output level

Set the audio monitor L

and R channel output
levels to +4 dB, 0 dB or +6
dB with menu switches No.
232 and No. 233.

(Illustrated example)
● L channel of the [AUDIO MONITOR] connectors and headphones: Output mixed

audio of the first, second and fourth channels.

● R channel of the [AUDIO MONITOR] connectors and headphones: Output the

audio from the third channel.

CH1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

SDI

AES/EBU

AUDIO INPUT / AUDIO MONITOR SELECT

L

ANALOG

R

● When the [AUDIO INPUT]

button is illuminated, the
channel indicator can be
used to select the input
audio signal.

71

● The recording level of this unit can be adjusted either fixedly or manually.

To adjust the recording level, pull out the [REC] volume controls to engage the
Manual mode and push in them to engage the Fixed (Unity) mode.
Either mode can be selected independently for each audio channel.

Fixed recording level adjustment

Push in the [REC] volume controls to engage the Unity mode for recording level
adjustment.
● In the Unity mode, the [R] indicator on the upper section of the meter lights. This

means that adjustment is not possible with the [REC] volume controls.

Manual recording level adjustment

● Pull out the [REC] volume controls to engage the Manual mode for recording

level adjustment.
In the Manual mode, the [R] indicator on the upper section of the meter goes out.

There are two ways to adjust recording levels manually.

1Adjust the audio level for each channel independently with the CH1 to CH4

[REC] volume controls.

2Use CH1 and CH2 [REC] volume controls as one pair and CH3 and CH4 [REC]

volume controls as one pair. Adjust the audio level with the CH1 and CH3 [REC]
volume controls as a master volume control and the CH2 and CH4 [REC] volume
controls as a balance control.

Select the adjustment mode with menu switch No. 215 <AUD REC VOLUME
MODE 1>.

Menu switch setting

● Select the manual recording level adjustment mode with menu switch No. 215

<AUD REC VOLUME MODE 1>.

“CH1/CH2/CH3/CH4 (0)”: To independently adjust the recording level for each

channel with CH1 to CH4 [REC] volume controls.

“MAS-1 BAL-2/,MAS-3 BAL-4 (1)”: Use CH1 and CH3 [REC] volume controls for

master volume control and the CH2 and CH4
[REC] volume controls for balance control.

7 RECORDING

7-4 AUDIO RECORD LEVEL ADJUSTMENT

● Recording level adjustment

in the Standby mode is
possible in the EE mode.

● During recording or audio

level adjustment, audio can
be monitored via the rear
panel [AUDIO MONITOR]
connectors or the front
panel [PHONES] jack. For
monitor output, refer to
page 70.

● When menu switch No. 215

[AUD REC VOLUME
MODE1] is set to “MAS-1
BAL-2/MAS-3 BAL-4”, the
master level adjust and
balance adjust functions
assigned to each volume
control are enabled even if
the corresponding channel
is in the Unity mode.

● The audio reference level

can be set with menu
switch No. 257 <AUD REF.
SIGNAL LEV.> (-20 dB or
-18 dB).

● Audio signal recording level can be adjusted.

1

2

POWER

ON

I

OFF

O

M

H

F

S

REC

MENU

PLAY

PAUSE/STILL

REW

STOP

FF

EJECT

PHONES

CH1

CH2

CH3

CH4

REC

PLAY

PULL FOR VARIABLE

TRACKING

CH1

CH1

CH2

CH3

CH4/

TRACKING

SET

HOLD

PB

PB/EE

COUNTER

UB

CONDITION

AUDIO
INPUT

VIDEO
INPUT

AUDIO

MONITOR

PULL
RELEASE

RESET

VCON

REMOTE

TOP

VIDEO

AUDIO

OTHERS

ON SCREEN

TIME CODE

SERVO/SYS

USER

INSERT

STAND BY

PLAYER

SEARCH

VAR

P.PLAY

DA3

DA2

DA1

VIDEO

ASSEM

IN

ENTRY

OUT

CANCEL

SHIFT

REVIEW

METER MODE

TRACKING

FINE

PREVIEW

AUTO EDIT

PREROLL

TC

RECORDER

DA4

VIDEO CASSETTE RECORDER

BR-D95U

STILL

X-1

REV

FWD

X1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

SIF

SDI

AES/EBU

AUDIO INPUT / AUDIO MONITOR SELECT

LINE

CPN

L

ANALOG

R

PULL

RELEASE

CTL

P.READ

AUTO OFF

V.VAR

REMOTE

PB/EE

16:9

TC UB DF SERVO

GEN

CF

AP

525

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

PHONES

CH1

CH2

CH3

CH4

REC

PLAY

PULL FOR VARIABLE

TRACKING

METER MODE

TRACKING

FINE

625

Variable Motion

COMPONENT DIGITAL

[REC] volume controls

Advertising