3 connections, 1 input connections, Off on 75 – JVC BR-D95U User Manual

Page 13

Advertising
background image

24

2-5 ON-SCREEN DISPLAY

2 CONTROLS, CONNECTORS AND DISPLAYS

Operation mode display in the Variable-
motion mode

Noiseless slow-motion playback is available at
speeds of -1.0 to +1.0 times normal.

● Variable-motion playback at speeds outside this range

(from -1.0 times to +1.0 times) results in a distorted
picture.

● When variable-motion playback is performed at speeds

outside the range from -1.0 times to +1.0 times, “!”
appears with the operation mode on the on-screen
display.

The “MUTING” or “CONDITION ALARM” can be shown on screen to make it easy to check VCR operating status
on the monitor connected to the [LINE 2- SUPER OUT] connector.
Ⅲ To display MUTING/CONDITION ALARM on screen, set menu switch No. 512 <MUTING/ALARM MESSAGE>

to “ON (1)”.

This can also be displayed even when setting the [ON SCREEN] switch on the sub panel to OFF.

Error rate degradation can also be checked with
the [CHANNEL CONDITION] indicator on the
front panel (refer to page 22).

Editing screen display

CTL

-0:00:00:01

Operation mode
● -1.0 times slow-motion

playback: VAR -1.0

● -1.5 times slow-motion

playback: !VAR -1.5

Monitor screen

● Tape remain is shown when the remaining time is less

than 25 minutes (approx.).

● This display automatically appears whenever an editing-

related button is pressed (such as selecting the edit mode).
(With menu switch No. 513 <EDIT ON SCREEN> set to
“ON”)

● When menu switch No. 513 <EDIT ON SCREEN> is set

to “ON”, press the [STANDBY] + [SHIFT] to switch the
edit screen ON/OFF.

MUTING/CONDITION ALARM display

CONDITION ALARM

(Menu switch No. 512 <MUTING/ALARM MESSAGE> set to “ON
(1)”)

CONDITION ALARM display

If video head output (error rate) is degraded during
playback, the “CONDITION ALARM” is shown on
screen.

● When the “CONDITION ALARM” is displayed,

perform manual tracking adjustment or cleaning
with the dedicated head cleaning tape.

MUTING display

● This unit outputs black signals from the built-in

signal generator via the <LINE 2 - SUPER OUT>
connector.
• In Record or EE mode:

When no video signal is input or input signals do not
contain a sync signal

• In Play mode:

When there are no recorded signals (no control signal
recorded) on the tape being played back (With menu
switch No. 120 <NO CTL MUTING> set to “ON”)

● When the input signal is a black signal or when a

tape on which a black signal is recorded is played
back, the monitor’s screen will be black.

To differentiate between the types of black screen
described above, “MUTING” appears on the screen
when the black screen is due to black signals output
from the built-in signal generator.

(Menu switch No. 512 <MUTING/ALARM MESSAGE> set to “ON (1)”)

MUTING

Monitor screen

R:SHTL STIL

DUR.

P:STOP

CTL

CTL
0:01:48:00

SPLIT
- :15:01

V•A1•A2•A3•A4•TC

Editing mode

Recorder current time

Tape remain

Player edit point

Player operation mode

Recorder operation mode

Player

current time

Audio

sprit time

Duration

Recorder edit point

Edit point registration

indications:

P
IN '
OUT
R
IN '
OUT'

:43:04

-0:00:51:03

0:01:48:00
0:01:31:04

0:00:00:00
0:00:43:04

E

F

+030
P
R

Variable mode
tape speed

R
IN
OUT

Show edit points

registered by pressing

the [ENTRY] button.

25

IN

CH1/2

CH1/2

CH3/4

CH3/4

OUT

IN

OUT

1

2

Y

Y

R-Y

B-Y

B-Y

R-Y

IN

OUT

OUT

OFF

ON

75

LINE1

LINE2

SUPER

RS-232C

COMPOSITE

LINE IN

REF

COMPONENT

COMPOSITE

REMOTE IN (9P)

REMOTE OUT (9P)

VIDEO CONTROL

CH1

CH2

CH3

CH4

CH2

CH3

CH4

CH1

IN

OUT

L

R

SERIAL V / A

SERIAL V / A

AES / EBU

AES / EBU

VIDEO

TIME CODE

AUDIO IN

AUDIO OUT

AUDIO MONITOR

3 CONNECTIONS

3-1 INPUT CONNECTIONS

[SERIAL V/A IN]
Install the optional SA-D95U digital interface board to
input signals to this connector.

[AUDIO IN]

Set the audio input reference level with menu
switches No. 224 to 227 <AUDIO IN LEVEL>.

[COMPONENT IN]
Accepts component video signals.

[AES/EBU IN]
Install the optional SA-D95U digital interface board to
input signals to this connector.

[TIME CODE IN]
To record the time code input from this connector, set
the [INT/EXT] switch on the sub panel to “EXT” and
menu switch No. 409 <EXT REGEN TC> to “LTC”.

Digital signal synchronization

The input digital signal must be synchronized with the
video signals. To do this, input sync signals to the
digital signal output unit and the [REF] connector of
this unit.

Reference sync signal

The servo system of this unit automatically selects
the reference signal as shown in the table below
depending on the setting of the menu switch and the
operation.

[REF]

[TIME CODE IN]

[COMPOSITE IN]

[SERIAL V/A IN]

[COMPONENT IN]

[AUDIO IN]

[AES/EBU IN]

Setting of menu
switch N. 003
<SYNC SELECT>

AUTO

EXT

Input sync signal

Operation

Video input [REF] input

Recording

r

؂

Playback

؂

r

Recording

r

R

Playback

؂

r

R

: Synchronizes (highest priority)

r

: Synchronizes.

؂: Does not synchronize.

• If video input and [REF] input are not available,

internal sync is performed.

Advertising