4 time code playback – JVC BR-D95U User Manual

Page 51

Advertising
background image

100

10-3 TIME CODE RECORDING

10 HOW TO USE TIME CODE

Front sub panel

Notes
● Drop/Non-drop Frame

mode selection (NTSC
only)

Automatically selected
according to the mode of
the received time code
(Drop Frame or Non-drop
Frame).

● Regeneration operation

• When time code is being

regenerated with input
time code, the built-in time
code generator stops
counting when no time
code is input.

● In the Play mode, time

code regeneration is based
on the playback time code
value.

● Inserting time code

If only time code data is
being inserted, record it on
the main time code. It is not
possible to insert it in the
sub time code.

1. Front sub panel switch setting

● Select the External Time Code Generator mode by setting the [INT/EXT]

switch to “EXT”.
The [FREE/REC] and [PRESET/REGEN] switch settings are not necessary.

● Select the Counter Display or On-screen Display mode to TC or UB with the

[COUNTER] and [SHIFT] buttons.

2. Menu switch setting

● Select the external time code to be regenerated.

● Menu switch No. 409 <EXT REGEN TC> (Initial setting: LTC (0))

LTC (0): Regenerates the LTC time code input through the rear panel

[TC IN] connector.

Input LTC time code should be regenerated (matched in
terms of sync and phase) with video signals. Make sure you
input an external sync signal to the feeding equipment.

VITC (1): Regenerates the VITC time code superimposed on the video

signal input through the rear panel VIDEO IN connector.

● User bit data selection

● Menu switch No. 457 <UB PRESET AUTO> (initial setting OFF (0))

OFF (0):

User bits regenerated by the time code generator of this unit is
recorded.

ON (1):

The user bit auto preset function is activated and the user bit
data stored in the built-in memory is recorded.

● Select the sub time code.

● Menu switch No. 450 <SUB TC (VITC) REC> (Initial setting: ON(1))

OFF (0):

“00:00:00:00” is always recorded on the sub time code.

ON (1):

Records the input VITC time code in the sub time code.

3. Record the time code.

Press the [PLAY] button while pressing the [REC] button.
[

The selected time code will be recorded.

Recording the time code data output from the external time code generator

Externally generated time code can be recorded after being regenerated with the
time code data output from the built-in time code generator.

POWER

ON

I

OFF

O

CH1

AUDIO
INPUT

VIDEO
INPUT

AUDIO

MONITOR

VIDEO CASSETTE RECORDER

BR-D95U

CH2

CH3

CH4

CH1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

SIF

SDI

AES/EBU

AUDIO INPUT / AUDIO MONITOR SELECT

LINE

CPN

L

ANALOG

R

SERVICE USE ONLY

TIME CDOE

INT

DF

FREE PRESET

EXT

NDF

REC

REGEN

Variable Motion

COMPONENT DIGITAL

OFF

RF

HID

GND

8

ON

ON

4

OFF

TIME CDOE

INT

FREE PRESET

EXT

DF

NDF

REC

REGEN

ON SCREEN

CF

(625)

101

10-4 TIME CODE PLAYBACK

10 HOW TO USE TIME CODE

Time code is output through the rear panel [TC OUT] and [VIDEO OUT] connectors during playback. VITC time
code with the time code data superimposed on the video signal is output through the [VIDEO OUT-LINE] connector.
Sub time code is output through the [VIDEO OUT-LINE] connector as VITC time code when menu switch No. 451
<VITC OUT SELECT> is set to “SUB TC”. Only the main time code is output through the [TC OUT] connector.

Setting

1. Front panel switch setting

● Select a Counter Display mode to TC or UB with the [COUNTER] and [SHIFT]

buttons.

2. Menu switch setting

● For VITC time code output, select a line to be added to the video signal.

● Menu switch No. 400 <VITC LINE-1 SELECT>

(Initial setting: NTSC 16 LINE/PAL 19 LINE)

● Menu switch No. 401 <VITC LINE-2 SELECT>

(Initial setting: NTSC 18 LINE/PAL 21 LINE )

● Select VITC time code output through the [VIDEO OUT] connector.

Menu switch No. 451 <VITC OUT SELECT>

SUB TC (0)

: Outputs the VITC time code recorded in the sub time code.

TC (1)

: Outputs the time code recorded in the main time code.

OFF

: VITC time code is not output from the [VIDEO OUT]

connector.

Factory setting : TC (1)

● Select the Time Code Output mode during search.

Menu switch No. 452 <SEARCH LTC>

OFF (0) : Outputs time code through the [TC OUT] connector during search

at X1.

ON (1) : Outputs time code through the [TC OUT] connector during search

at all speeds. Continuous time code is not available.

3. Play back the time code.

Press the [PLAY] button.

[

The selected time code is played back.

TCR or UBR is shown with the on-screen time code data.
● LTC time code is output from the [TC OUT] connector.

● Main or sub time code selected with menu switch No. 451 <VITC OUT

SELECT> is superimposed on video signals and output to the line selected
with menu switch No. 400 and No. 401 from the [VIDEO OUT] connector.

● On-screen display of sub

time code

Sub time code is displayed
with the main time code
when menu switch No. 451
<VITC OUT SELECT>
is set to “SUB TC (0)”.

POWER

ON

I

OFF

O

M

H

F

S

REC

MENU

PLAY

PAUSE/STILL

REW

STOP

FF

EJECT

PHONES

CH1

CH2

CH3

CH4

REC

PLAY

PULL FOR VARIABLE

TRACKING

CH1

CH1

CH2

CH3

CH4/

TRACKING

SET

HOLD

PB

PB/EE

COUNTER

UB

CONDITION

AUDIO
INPUT

VIDEO
INPUT

AUDIO

MONITOR

PULL
RELEASE

RESET

VCON

REMOTE

TOP

VIDEO

AUDIO

OTHERS

ON SCREEN

TIME CODE

SERVO/SYS

USER

INSERT

STAND BY

PLAYER

SEARCH

VAR

P.PLAY

DA3

DA2

DA1

VIDEO

ASSEM

IN

ENTRY

OUT

CANCEL

SHIFT

REVIEW

METER MODE

TRACKING

FINE

PREVIEW

AUTO EDIT

PREROLL

TC

RECORDER

DA4

VIDEO CASSETTE RECORDER

BR-D95U

STILL

X-1

REV

FWD

X1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

SIF

SDI

AES/EBU

AUDIO INPUT / AUDIO MONITOR SELECT

LINE

CPN

L

ANALOG

R

PULL

RELEASE

CTL

P.READ

AUTO OFF

V.VAR

REMOTE

PB/EE

16:9

TC UB DF SERVO

GEN

CF

AP

525

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

625

Variable Motion

COMPONENT DIGITAL

[PLAY] button

[COUNTER] button

● When you are using this

deck as a player, the
recording time code may
not be regenerated when
you output embedded
audio (SERIAL V/A OUT)
signals to the BR-D750U,
BR-D85U or BR-D80U. In
this case, set menu switch
No. 237 <EMBEDDED
AUDIO> to “OFF”.

Advertising