2 video signal system selection, 3 menu switch setting, Mh f s rec menu play pause/still rew stop ff eject – JVC BR-D95U User Manual

Page 16: Still x-1 rev fwd x1, Component digital, Menu, Reset vcon remote, Insert, Tracking fine, Video cassette recorder

Advertising
background image

30

4-2 VIDEO SIGNAL SYSTEM SELECTION

This unit can be used with either the NTSC or PAL signal systems. The currently selected video signal system is
indicated by the 525/625 indicator on the counter display. To change the video signal system, follow the steps
below.

POWER

ON

I

OFF

O

M

H

F

S

REC

MENU

PLAY

PAUSE/STILL

REW

STOP

FF

EJECT

PHONES

CH1

CH2

CH3

CH4

REC

PLAY

PULL FOR VARIABLE

TRACKING

CH1

CH1

CH2

CH3

CH4/

TRACKING

SET

HOLD

PB

PB/EE

COUNTER

UB

CONDITION

AUDIO
INPUT

VIDEO
INPUT

AUDIO

MONITOR

PULL
RELEASE

RESET

VCON

REMOTE

TOP

VIDEO

AUDIO

OTHERS

ON SCREEN

TIME CODE

SERVO/SYS

USER

INSERT

STAND BY

PLAYER

SEARCH

VAR

P.PLAY

DA3

DA2

DA1

VIDEO

ASSEM

IN

ENTRY

OUT

CANCEL

SHIFT

REVIEW

METER MODE

TRACKING

FINE

PREVIEW

AUTO EDIT

PREROLL

TC

RECORDER

DA4

VIDEO CASSETTE RECORDER

BR-D95U

STILL

X-1

REV

FWD

X1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

SIF

SDI

AES/EBU

AUDIO INPUT / AUDIO MONITOR SELECT

LINE

CPN

L

ANALOG

R

PULL

RELEASE

CTL

P.READ

AUTO OFF

V.VAR

REMOTE

PB/EE

16:9

TC UB DF SERVO

GEN

CF

AP

525

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

625

525
625

Variable Motion

COMPONENT DIGITAL

[HOLD] button

[SEARCH] button

[MENU] button

[SET] button

: NTSC

: PAL

Jog dial

4 MENU SWITCH SETTING

Operation procedure

1. Press the [MENU] button to display the top

menu.

2. Turn the jog dial to select “D95: 525/625”.

“D95” is shown on the counter display and “D95”
blinks on screen.

3. Hold the [SEARCH] button down and turn the

jog dial to select the set value.
Select “525” for NTSC or “625” for PAL.

4. To change the menu switch setting, hold the

[SET] button down and press the [HOLD]
button.
[

The Normal Display mode is restored.

5. To apply the selected video signal system, turn

this unit OFF then ON again.
[

When the power is turned ON, the video signal
system is changed and the corresponding
video signal system indicator is shown on the
counter display (525 or 625 indicator).

• When a cassette tape recorded on a signal system other than that set for this unit is played back, the

corresponding indicator ([525] or [625]) blinks.
When the NTSC system is selected and a PAL tape is played back, the [625] indicator blinks.
When the PAL system is selected and an NTSC tape is played back, the [525] indicator blinks.

• If required, select the audio reference level (-20 dB/-18 dB) for recording with menu switch No. 257 <AUD.

REF. SIGNAL LEV. >. (See page 54.)

Video signal system indicator

[Counter display]

[On-screen display]

D95:525/625

00A:MENU SETTING

SET+HOLD INITIAL

00B:DIRECT ACCESS

SET+HOLD>ON

00C:USER PAGE

SET+HOLD>INITIAL

00D:MENU LOCK

SET+HOLD>OFF

M

H

F

S

SET+HOLD[POWER OFF>525

D95:525/625

00A:MENU SETTING

SET+HOLD INITIAL

00B:DIRECT ACCESS

SET+HOLD>ON

00C:USER PAGE

SET+HOLD>INITIAL

00D:MENU LOCK

SET+HOLD>OFF

M

H

F

S

SET+HOLD[POWER OFF>525

31

D95:525/625

SET+HOLD[POWER OFF>525

00A:MENU SETTING

SET+HOLD INITIAL

00B:DIRECT ACCESS

SET+HOLD>ON

00C:USER PAGE

SET+HOLD>INITIAL

00D:MENU LOCK

SET+HOLD>OFF

002:OPERATION LOCK

OFF

003:SYNC SELECT

AUTO

005:AUTO TRACKING

ON

300:DIRECT EJECT

ON

301:DIRECT SEARCH

ON

302:BACK SPACE

ON

307:PAUSE/STILL/STP TIME

311:AUTO PLAY

OFF

300:DIRECT EJECT

OFF

301:DIRECT SEARCH

ON

302:BACK SPACE

ON

307:PAUSE/STILL/STP TIME

311:AUTO PLAY

OFF

M

H

F

S

M

H

F

S

M

H

F

S

M

H

F

S

008:CAP LOCK(525)

SW SEL

009:CAP RE-LOCKING DIR.

ACCELERATION

5MIN

5MIN

4-3 MENU SWITCH SETTING

4 MENU SWITCH SETTING

[Counter display]

[On-screen display]

Menu switch setting
display

Top menu display

Operation procedure

1. Call up the menu switch setting display.

Press the [MENU] button to call up the menu
screen on the counter display and on-screen
display. When the top menu is displayed, turn the
jog dial to show the menu switch setting screen.
● On-screen display data are output through the

rear panel [LINE2-SUPER] connector.

The counter display shows menu switch number.

2. Select a menu switch item to set by turning the

jog dial.
● The selected menu switch number blinks on the

on-screen display.

● The menu switch number changes on the

counter display.

3. Select the setting value of the menu switch by

turning the jog dial while pressing the
[SEARCH] button.
Repeat steps 2 and 3 to change other items.

4. Press the [SET] button to enter the finalized

settings in memory.
● During setting, “SET” blinks on the counter

display and “MENU SET” blinks on the on-
screen display. When setting is complete, the
normal screen is restored.

Menu switch No. Set value No.

POWER

ON

I

OFF

O

M

H

F

S

REC

MENU

PLAY

PAUSE/STILL

REW

STOP

FF

EJECT

PHONES

CH1

CH2

CH3

CH4

REC

PLAY

PULL FOR VARIABLE

TRACKING

CH1

CH1

CH2

CH3

CH4/

TRACKING

SET

HOLD

PB

PB/EE

COUNTER

UB

CONDITION

AUDIO
INPUT

VIDEO
INPUT

AUDIO

MONITOR

PULL
RELEASE

RESET

VCON

REMOTE

TOP

VIDEO

AUDIO

OTHERS

ON SCREEN

TIME CODE

SERVO/SYS

USER

INSERT

STAND BY

PLAYER

SEARCH

VAR

P.PLAY

DA3

DA2

DA1

VIDEO

ASSEM

IN

ENTRY

OUT

CANCEL

SHIFT

REVIEW

METER MODE

TRACKING

FINE

PREVIEW

AUTO EDIT

PREROLL

TC

RECORDER

DA4

VIDEO CASSETTE RECORDER

BR-D95U

STILL

X-1

REV

FWD

X1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

SIF

SDI

AES/EBU

AUDIO INPUT / AUDIO MONITOR SELECT

LINE

CPN

L

ANALOG

R

PULL

RELEASE

CTL

P.READ

AUTO OFF

V.VAR

REMOTE

PB/EE

16:9

TC UB DF SERVO

GEN

CF

AP

525

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

625

Variable Motion

COMPONENT DIGITAL

[MENU] button

[HOLD] button

[SET] button

Jog dial

Advertising