8 PLAYBACK

8-11 FF, REW AND COUNTER MEMORY FUNCTIONS

POWER

ON

I

OFF

O

M

H

F

S

REC

MENU

PLAY

PAUSE/STILL

REW

STOP

FF

EJECT

PHONES

CH1

CH2

CH3

CH4

REC

PLAY

PULL FOR VARIABLE

TRACKING

CH1

CH1

CH2

CH3

CH4/

TRACKING

SET

HOLD

PB

PB/EE

COUNTER

UB

CONDITION

AUDIO
INPUT

VIDEO
INPUT

AUDIO

MONITOR

PULL
RELEASE

RESET

VCON

REMOTE

TOP

VIDEO

AUDIO

OTHERS

ON SCREEN

TIME CODE

SERVO/SYS

USER

INSERT

STAND BY

PLAYER

SEARCH

VAR

P.PLAY

DA3

DA2

DA1

VIDEO

ASSEM

IN

ENTRY

OUT

CANCEL

SHIFT

REVIEW

METER MODE

TRACKING

FINE

PREVIEW

AUTO EDIT

PREROLL

TC

RECORDER

DA4

VIDEO CASSETTE RECORDER

BR-D95U

STILL

X-1

REV

FWD

X1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

SIF

SDI

AES/EBU

AUDIO INPUT / AUDIO MONITOR SELECT

LINE

CPN

L

ANALOG

R

PULL

RELEASE

CTL

P.READ

AUTO OFF

V.VAR

REMOTE

PB/EE

16:9

TC UB DF SERVO

GEN

CF

AP

525

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

625

Variable Motion

COMPONENT DIGITAL

[SET] button

[FF]
button

[REW]
button

[PREROLL]
button

To fast-forward or rewind the tape

Press the [FF] or [REW] button.

[

The [FF] or [REW] button lights and the tape is fast-forwarded or rewound.

Maximum FF and REW speeds can be set to 60 times, 32 times or 17 times
normal with menu switch No. 319 <FF/REW MAX SPEED>. Factory setting:
60 times normal

Counter memory function

Setting procedure

● Set the counter mode to “CTL” with the front panel [COUNTER] button.

Counter memory operation

1. Specify a tape section to be recalled.

Press the [RESET] button while pressing the [SET] button at the desired
section.
[

The counter is reset to “0:00:00:00” and this section is entered in this unit.

* When the counter display mode is set to “TC”, the value at the specified

point is entered.

• Press the [SET] button to check the entered value on the counter display.

2. Start Counter Search.

In the Stop mode, press the [PREROLL] button while pressing the [SET]
button.
The tape fast-forwards or rewinds and stops automatically at or near counter
0:00:00:00 in CTL mode.
In time code mode, the tape stops automatically at or near the entered value.

Notes
Output mode selection in FF
and REW modes
With menu switch No. 314
<PB/EE MODE> set to
“STOP/FF/REW (0)”, press
the [PB/EE] button to engage
the Still Output mode or EE
mode.

Auto REW function setting
With menu switch No. 312
<AUTO REW>

The tape is automatically
rewound to the start when it
comes to an end in the Play
or Record mode.

8-12 REPEAT PLAYBACK

With this function activated, tape playback is automatically repeated when the tape
ends.

Setting

● Set menu switch No. 311 <AUTO PLAY> to “ON (1)”

● Set menu switch No. 312 <AUTO REW> to “ON (1)”

Ⅲ Start playback

When the tape ends, it is rewound to the start and automatically begins
playback. This procedure is repeated continuously.

87

9 OTHER FUNCTIONS

2 extra lines for color signals and 4 extra lines for black and white signals are provided for each frame. A data
added to the V blanking section of input signals is recorded on the tape as an extra line. In the Play mode, this
extra line information is added to the video signal for output.

● Menu switch indication for

extra line
NTSC : (525) is displayed

after the menu
switch name.

PAL

: p is displayed after

the menu switch
number and (625) is
displayed after the
menu switch name.

● For details of menu

switches No. 138 to No.
142, refer to page 47.

9-1 EXTRA LINE DATA RECORDING/PLAYBACK

Extra line recording

Select the line containing the information to be recorded on an extra line.

1. Setting the input signal line for extra-line recording

Select with menu switch No. 138 <EXTRA LINE REC>.

FIX (0)

USER SETTING
(1)

NTSC: Records line 22 information in the input

signal onto extra line-1 and line 284
information onto extra line-2. Factory
setting.

PAL

: Records line 22 information in input signals

onto extra line-1 and line 623 information
onto extra line-2. Factory setting.

Two user-specified lines in the input signal are
recorded onto extra line-1 and 2 for color signal
data. Four user-specified lines in the input signal
are recorded onto the extra line-1 to 4 for black-
and-white data.
To specify the lines for color signals, set menu
switches No. 139 and No. 140. For black-and-white
signals, set menu switches No. 139 to No. 142.

2. Selecting an input signal line when USER SETTING (1) is selected in

Step 1.
● Set the line to record on extra line-1 with menu switch No. 139 <EXTRA-L R1

SEL> (color or black-and-white signal).

● Set the line to record on extra line-2 with menu switch No. 140 <EXTRA-L R2

SEL> (color or black-and-white signal).

● Set the line to record on extra line-3 with menu switch No. 141 <EXTRA-L R3

SEL> (black-and-white signal only).

● Set the line to record on extra line-4 with menu switch No. 142 <EXTRA-L R4

SEL> (black-and-white signal only).

Advertising