5-2 MENU SWITCH SETTING CONTENT

5 MENU SWITCH SETTING DETAILS

[ ] : Factory setting

Menu SW

On-screen

Counter

On-screen

No.

display

display

display

512

MUTING/ALARM

[0]

[OFF]

MESSAGE

1

ON

513

EDIT ON

0

OFF

SCREEN

[1]

[ON]

601

V.BLANK MASK

0

OFF

[1]

[ON]

2

ON WITH
0.5H

620

DUBBING LOOP

[0]

[OFF]

1

3 TIMES

2

5 TIMES

3

10 TIMES

Selects whether “MUTING” or “CONDITION
ALARM” messages appear On-Screen.This menu
makes it easier to check the VCR’s operation
status.
The on-screen display is shown on the monitor
connected to the [VIDEO MONITOR OUT]
connector.
OFF : The “MUTING” and “CONDITION ALARM”

are not displayed.

ON : The “MUTING” and “CONDITION ALARM”

are displayed.

For more details, refer to the “MUTING/
CONDITION ALARM” display on page 24.

Selects whether the edit on-screen display is ON or
OFF during editing. On-screen information is output
from the [LINE2 SUPER OUT] connector.
OFF : Does not show the edit on-screen display

during editing.

ON : Show the edit on-screen display during

editing.

<TBC. FRAME MEMORY>

Enables/disables masking of the vertical interval.
OFF

: No masking.

ON

: Masks the vertical interval.

ON WITH 0.5H : Masks section for 0.5H in addition

to the vertical interval (analog
signals only).

* When this menu is set to “OFF”, only the

recordable sections of the signals output for V.
blanking in the EE mode are output (VITC,
EXTRA LINE, EXTENSION LINE).
When this menu is set to “ON”, VITC and EXTRA
LINE have priority in each menu setting (refer to
page 89).

Selects whether or not the multi-generation test
“Dubbing Loop Function” is used to aid adjusting an
analog component system to unity gain. When this
mode is active, the VCR automatically switches to
its internal color bar generator and continuously
builds the number of generations selected.
OFF

: The dubbing loop function is disabled.

3 TIMES : The dubbing loop function repeatedly

builds 3 generations every few seconds.

5 TIMES : The dubbing loop function repeatedly

builds 5 generations every few seconds.

10 TIMES : The dubbing loop function repeatedly

builds 10 generations every few
seconds.

* When set to any setting except OFF (0), this unit

enters the Dubbing Loop mode.

* For more details on the dubbing loop function,

refer to page 122.

Item

Content

Setting

65

6 PREPARATION

6-1 OPERATION MODE LOCK

This unit is provided with an operation mode lock facility. This function prevents accidental changes to switch and
control settings. When this function is ON, currently selected modes and knob or switch positions cannot be
adjusted.

● Use menu switch No. 002 <OPERATION LOCK> to enable this function.

● With this function enabled, operation of all front panel control buttons, adjustment knobs, dials and switches is

disabled and changes to menu switch settings are not possible. When this function is activated, it is not possible
to change menu switch settings. However, the [PHONES LEVEL] control and menu switch No. 002
<OPERATION LOCK> (to release the operation mode lock function) can be used.

Procedure

1. Make all desired settings and operate as usual.

2. Engage the operation lock function.

1 Press the [MENU] button to call up the menu setting display.

2 Turn the jog dial and select menu switch No. 002 <OPERATION LOCK>.

If the Direct Access facility is ON, press the [STAND BY] button to call up the
menu item display more quickly.

3 Select “ON (1)” by turning the jog dial while pressing the [SEARCH] button.

4 Press the [SET] button.

The operation lock function is ON.
After the SET indication blinks for several seconds, the normal counter and
on-screen displays are restored.

3. To cancel the operation mode lock facility, set menu switch No. 002

<OPERATION LOCK> to “OFF (0)”.

POWER

ON

I

OFF

O

M

H

F

S

REC

MENU

PLAY

PAUSE/STILL

REW

STOP

FF

EJECT

PHONES

CH1

CH2

CH3

CH4

REC

PLAY

PULL FOR VARIABLE

TRACKING

CH1

CH1

CH2

CH3

CH4/

TRACKING

SET

HOLD

PB

PB/EE

COUNTER

UB

CONDITION

AUDIO
INPUT

VIDEO
INPUT

AUDIO

MONITOR

PULL
RELEASE

RESET

VCON

REMOTE

TOP

VIDEO

AUDIO

OTHERS

ON SCREEN

TIME CODE

SERVO/SYS

USER

INSERT

STAND BY

PLAYER

SEARCH

VAR

P.PLAY

DA3

DA2

DA1

VIDEO

ASSEM

IN

ENTRY

OUT

CANCEL

SHIFT

REVIEW

METER MODE

TRACKING

FINE

PREVIEW

AUTO EDIT

PREROLL

TC

RECORDER

DA4

VIDEO CASSETTE RECORDER

BR-D95U

STILL

X-1

REV

FWD

X1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

CH1

CH2

CH3

CH4

SIF

SDI

AES/EBU

AUDIO INPUT / AUDIO MONITOR SELECT

LINE

CPN

L

ANALOG

R

PULL

RELEASE

CTL

P.READ

AUTO OFF

V.VAR

REMOTE

PB/EE

16:9

TC UB DF SERVO

GEN

CF

AP

525

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

OVER

–60

–2

–4

+2

+4

0

–40

–30

–20

–10

0

dB

dB

R

P

625

Variable Motion

COMPONENT DIGITAL

[MENU] button

[HOLD] button

[SET] button

Jog dial

[SEARCH] button

Advertising