Communication protocol (serial interface)

This function selects the appropriate communications protocol. Refer to the specification of
your host system for selecting proper communication protocol.

Note: The XON/XOFF 1 differs from the XON/XOFF 2 in that the XON code (11h) is sent
from the printer at power-on in the XON/XOFF 1 protocol.

Communication speed (serial interface)

This function selects the appropriate baud rate for the data transmission speed.

Serial error check (serial interface)

This function selects the printer's response to a serial data transmission error. The serial data
transmission error includes a parity error, framing error, and over-run error. If "PRINT" is
enabled, the data in error is printed as an asterisk(*). If "IGNORED" is enabled, the data in
error is discarded.

48

5. Extended setup options (34-36)

36 SERIAL ERROR

S.ERROR: PRINT

S.ERROR:IGNORED

35 BAUD RT

SPEED: 9600 BPS

SPEED: 4800 BPS

SPEED: 2400 BPS

SPEED: 1200 BPS

34 PROTOCOL

DTR

XON/OFF1

XON/OFF2

ETX/ACK

....................

Busy/Ready protocol

....................

Set XON/XOFF 1.

....................

Set XON/XOFF 2.