66

A. Specifications

Parallel interface specifications

Input connector

Notes:

1. HIGH is pulled up to + 5V by 2.2k

Ω resistor.

2. NC stands for no connection.
3. CHASSIS GND and GND are connected in the printer.

Data input timing chart

STROBE

DATA 1 -DATA 8

BUSY

ACK

1 - 50 µs

min. 1 µs

max. 0.5 µs

3 - 7 us

min. 0 µs

6 - 10 µs

3 - 7 µs

PIN

SIGNAL

IN/OUT

PIN

SIGNAL

IN/OUT

1

STROBE

IN

19

GND

2

DATA 1

IN

20

GND

3

DATA 2

IN

21

GND

4

DATA 3

IN

22

GND

5

DATA 4

IN

23

GND

6

DATA 5

IN

24

GND

7

DATA 6

IN

25

GND

8

DATA 7

IN

26

GND

9

DATA 8

IN

27

GND

10

ACK

OUT

28

GND

11

BUSY

OUT

29

GND

12

PE

OUT

30

GND

13

SELECT

OUT

31

INITIAL

IN

14

AUTOFEED

IN

32

ERROR

OUT

15

NC

33

NC

16

NC

34

NC

17

CHASSIS GND

35

NC

18

+5 V (max. 200mA)

36

NC

min. 1 µs

1817 1615141312 1110 9 8 7 6 5 4 3 2 1

3635 3433323130 2928 2726252423 22 212019

Advertising