Seiko Group BP-6000 User Manual

Page 97

Advertising
background image

90

ITEM Mode

Code & Hexadecimal

n: (Hex.) = selection

[1]

BAR CODE data

DC4, DC4, B, n

Specifies the numler ("n") of data to be regarded as

sequence

14, 14, 42, n

bar code data.

0 < n < 44H

[2]

Check digit

DC4, DC4, C, n

Selects/deselects to add a check digit automatically.

14, 14, 43, n

n: 00=No,

01=Yes.

[3]

Element

DC4, DC4, E, n1, n2

Changes the width of a bar, space, or intercharacter

variables

14, 14, 45, n1, n2

gap. n1 specifies the type of element and n2 sets

variable width in n2/120 inches.
This command is not effective in postnet bar code.
n1: 00=Narrow bar

01=Wide bar
02=Narrow space
03=Wide space
04=Intercharacter gap (ICG)

n2: n2/120" (1

n2

127)

[4]

HRI font

DC4, DC4, F, n

Selects HRI character font.

14, 14, 46, n

This command is not effective in postnet bar code.
n: 00=Current selected font

[5]

Bar code height

DC4, DC4, H, n

Sets bar code height to n/12 inch (1

n

120).

14, 14, 48, n

This command is not effective in postnet bar code.
If n

4, HRI print is disabled.

[6]

HRI print

DC4, DC4, I, n

Selects HRI character not to be printed or to be printed

14, 14, 49, n

below or above bar code.
This command is not effective in postnet bar code.
n: 00=No print

01=Below bar code
02=Above bar code

[7]

Bar code type

DC4, DC4, T

Selects a bar code type.

14, 14, 54, n

n: 00=Industrial 2/5, n:

07=Code 128,

01=Interleave 2/5,

08=EAN 8,

02=Matrix 2/5,

09=EAN 13,

03=Codabar,

0A=UPC-A,

04=Code 11,

0B=UPC-E,

05=Code 39,

0C=Postnet

06=Code 93,

FF=Element

[8]

Guard bar

DC4, DC4, G, n

Euables/disables the guard bar extension (long bar).

extension

14, 14, 47, n

in EAN and UPC.
n: 00=Disable guard bar extension

01=Enable guard bar extension (default)

[9]

Start/stop char.

DC4, DC4, N, n

Assigns the start and stop character for the Codabar.

assignment

14, 14, 4E, n

n: 00=Start character

01=Stop character

n: 02={"a", "b", "c", "d", "e", "t", "n", "*"}
Default is "a" as the start and stop character

[10]

Start/stop char.

DC4, DC4, S, n

Selects to print the start and stop character as HRI for

print

14, 14, 53, n

Codabar, Code 11, Code 39, and Code 93.
n: 00=To print(default)

01=Not to print

[11]

Code 128

DC4, DC, V, n

Selects code sequence in Code 128 to be treated as a

code sequence

14, 14, 56, n

character value or as a character code.
n: 00=character code(default)

01=character value

[12]

Bar code end

ESC SO

Indicates the end of bar code data sequence.

sequence

1B, 0E

This sequence is valid when
#27 BAR CODE is to MODE2
in the SUB-MENU of SETUP MODE.

[13]

Bar code start

ESC SI

Treats the following immediate data as a bar code.

sequence

1B, 0F

This sequence is valid when
#27 BAR CODE is to MODE2
in the SUB-MENU of SETUP MODE.

B. Control code summary (bar code)