5. Interface Specifications

SATO RISC Printers

171

from being full). At this time, DTR will go “high” or an X-On is sent to tell
the host that it can again receive data.

All printer error conditions (i.e., label out, ribbon out) will cause the printer
to go busy (DTR “low” or X-Off) until the problem is corrected and the
printer is placed on-line. The printer will also be busy if taken off-line from
the front panel.

5.4 RS232C Serial Interface

General Specifications

Asynchronous ASCII

Half-duplex communication.
Ready/Busy Hardware Flow Control
Pin 20, DTR Control
Pin 4, RTS Error Condition
X-On/X-Off Software Flow Control.
Bi-Directional communication (ENQ/Response)

Data Transmission Rate

2400, 4800, 9600 and 19200 bps

Character Format

1 Start Bit (fixed)
7 or 8 data bits (selectable)
Odd, Even or No Parity (selectable)
1 or 2 Stop bits (selectable)

DTR Low or

X-Off

Buffer Available

DTR High or

X-On

0

56K

64K