Replace data (partial edit) – SATO XL400/410 User Manual

Page 82

Advertising
background image

82

SATO RISC Printers

2. Command Codes

Programming Manual

Replace Data (Partial Edit)

Command Structure:

<ESC>0 (<ESC>zero)
Example:

See above

Placement:

Must follow <ESC>A and precede all other print data

Default:

None

Function:

To replace a specified area of the previous label with new data. This
command will cause the previous label to print along with any changes
specified within the current data stream.

Input:

<ESC>A

<ESC>H0025<ESC>V0020<ESC>W0BCL 608

<ESC>H0025<ESC>V0085<ESC>WB1M8485S

<ESC>H0025<ESC>V0150<ESC>WL0M8490S

<ESC>H0025<ESC>V0215 <ESC>WL1M8460S

<ESC>Q1<ESC>Z

<ESC>A

<ESC>0<ESC>H0025<ESC>V0020<ESC>WB0M8459S<ESC>Q1<ESC>Z

Output:

Note:
1. Specify the exact same parameters for the image to be replaced

as were specified in the original data stream, including rotation,
expansion, pitch, etc. This will ensure that the new data will
exactly replace the old image. If the replacement data contains

Advertising