Set rs232 parameters – SATO CX208/212 User Manual

Page 101

Advertising
background image

Set RS232 Parameters

Command Structure

<ESC>CRaaaaa,b,c,d

aaaaa =

Baud Rate (2400, 4800, 9600,19200 or 38400)

b

=

Parity (N for None, O for Odd, E for Even)

c

=

Number of data bits (7 or 8)

d

=

Number of stop bits (1 or 2)

Example:

ESC>CR9600,N,8,1

Placement:

Must be sent in a separate data stream.

Default:

9600,N,8,1

Command Function

To select the desired RS232 communications settings

Input to Printer

<ESC>A

<ESC>CR9600,N,8,1

<ESC>Z

Printer Output

There is no printer output as a result of this command.

Special Notes

1. Any commands sent to the printer over the RS232 port within two

seconds of receiving this command may be lost.

2. The RS232 settings must match those of the host system. If the

RS232 settings are unknown, printing a Self Test label will list the
current printer settings.