Auto-calibrate – SATO CX208/212 User Manual

Page 92

Advertising
background image

Auto-Calibrate

Command Structure

<ESC>CFa

a

=

0

Disable Auto-Calibrate

1

Enable Auto-Calibrate

Example:

<ESC>CF1

Placement:

This command should be sent in a separate data
stream.

Default:

Enabled

Command Function

To enable/disable the Auto-Calibrate function.

Input to Printer

<ESC>A

<ESC>CF1

<ESC>Z

Printer Output

Theres is no printer output as a result of this command.

Special Notes

1. When Auto-Calibrate is enabled, the printer will automatically

attempt to calibrate when it detects an out-of-paper condition (10"
of platen feed after a label is printed without detecting a label edge
or sense mark). If the calibration is successful, the printer shall
move paper to the next index mark and resume normal
operations. If the calibration is not successful, the printer shall
indicate an out-of-paper condition by a red READY LED. The
printer shall restore the original index circuit settings.

2. See “Label Sensing” on page 8 for more information on

calibration.