Set Sensor Type

Command Structure

<ESC>CIa

a

=

0

Disable Sensor

1

Reflective (Eye-Mark ) Sensing

2

Transmissive (Label Gap or Notch) Sensing

Example:

<ESC>CI1

Placement:

This command should be sendt in a separate data

stream.

Default:

<ESC>CI2 (Transmissive Sensing)

Command Function

To select the top-of-label sensing method.

Input to Printer

<ESC>A

<ESC>CI2

<ESC>Z

Printer Output

Theres is no printer output as a result of this command.

Special Notes

1. The reflective Eye-Mark must be a minimum of .125" wide and at

least 1.0" long. It should be parallel to the platen and centered on
the underneath side of the label

2. The transmissive gap must be a minimum of 0.125" wide.

3. See “Sensing” on page 8 for more information on label indexing.