Calibrate Sensor

Command Structure

<ESC>CA

Example:

<ESC>CA

Placement:

This command should be sent after the sensor type
has been selected with the <ESC>CI command. It

should

not be included with print job commands.

Default:

There is no default for this command.

Command Function

To adjust the label sensor for unique media and ribbon combinations.

Input to Printer

<ESC>A

<ESC>CI2

<ESC>CA

<ESC>Z

Printer Output

There is no printer output for this command. It will cause the printer to
feed a label while the characteristics of the label backing or eye-mark
are measured.

Special Notes

1. The sensor is calibrated for the currently selected sensor type

(Eye-Mark or Transmissive).

2. If the Sensor is disabled with a <ESC>CI0 command, no

calibration is performed.

3. The sensor must be recalibrated whenever the sensor type is

changed.

4. When calibrating the sensor for the CX200/212TT Thermal

Transfer unit operating in the thermal transfer mode, the ribbon
must be installed in the printer.

Page 90

PN 9001092 Rev. A

SATO CX208/212 Printers