Custom protocol command codes download – SATO CX208/212 User Manual

Page 95

Advertising
background image

Custom Protocol Command Codes

Download

Command Structure

<ESC>LD,a,b,c,d,e,f,g,h,i

a

=

Replacement character for STX in ASCII or hex format

b

=

Replacement character for ETX in ASCII or hex format

c

=

Replacement character for ESC in ASCII or hex format

d

=

Replacement character for ENQ in ASCII or hex format

e

=

Replacement character for CAN in ASCII or hex format

f

=

Replacement character for NULL or ~ in ASCII or hex
format

g

=

Replacement character for OFFLINE in ASCII or hex

format

Example:

<ESC>LD,{,},%,#,&,*,~,0,0

Placement:

Immediately following the <ESC>A Start command and

in

an independent data stream.

Default:

Standard Protocol command Codes

Command Function

Allows the user to defines custom Protocol Command codes.

Printer Input

<ESC>A

<ESC>LD,{,},%,#,&,*,~,0,0

<ESC>Z

Printer Output

A Protocol Command code status label will be printed as a result of
the a successful download of a custom set of Protocol Command
codes.

Special Notes

1. Commas must be used to separate the parameters. If a parameter

is omitted between two commas, the default Non-Standard
Protocol Command codes for that parameter will be used.

Page 91

PN 9001092 Rev. A

SATO CX208/212 Printers

CX208/212 Programming Guide

STX = 7B

ETX = 7D ESC = 25

ENQ = 23

CAN = 26 NULL = 2A

OFFLINE = 7E

Press the “FEED” key to activate the User
Default or power the printer off to ignore
them.

Advertising