Special requirements for india, 93 d, A n 9 3 – Silicon Laboratories SI2493/57/34/15/04 User Manual

Page 146

Advertising
background image

A N 9 3

146

Rev. 1.3

6.2.2.3. Special Requirements for India

To output a 0 dBm sine wave, use the following commands:

AT:PF800, C4DD, 7B5C, 595F

AT*Y254:W50, 0, 5B86,1

AT:U46,0

AT*Y1X1DT1

This command string turns off the high-frequency DTMF tone, leaving only the low-frequency DTMF tone when an
ATDT is sent. The tone is output continuously until any key is pressed. To restart the tone output, type AT*Y1DT1.
To change the tone power level, type ATU46,00X0 (where X is a hexadecimal value 0–F representing output power
in –1 dBm steps from 0 to –15 dBm).

Table 92. Dial Registers

Register

Value

Function

Pulse Dial Control

U37–U40

Pulse per Digit Definition

U42

PDBT

Pulse Dial Break Time

U43

PDMT

Pulse Dial Make Time

U45

PDIT

Pulse Dial Interdigit Time

DTMF Control

U46

DTPL

DTMF Power Level (and
Twist)

U47

DTNT

DTMF On Time

U48

DTFT

DTMF Off Time

Table 93. Line Interface/Control Registers

Register

Bit

Value

Function

U4D

10

CLPD

Check Loop Current Before
Dialing

1

LLC

Low Loop Current Detect
(set for legacy TBR21)

0

LCN

Loop Current Needed

U50

LCDN

Loop Current Debounce
On Time

U51

LCDF

Loop Current Debounce
Off Time

U52

XMTL

Transmit Level

U67:

13:12

MINI

9 ILIM

7

DCR

DC Impedance Select

6

OHS

On-Hook Speed

3:2

DCV

DC Termination Select

1

RZ

Ringer Impedance

0

RT

Ringer Threshold Select

U68

2

BTE

Billing Tone Protect Enable

1

ROV

Receive Overload

0

BTD

Billing Tone Detected

Advertising
This manual is related to the following products: