An93 – Silicon Laboratories SI2493/57/34/15/04 User Manual

Page 163

Advertising
background image

AN93

Rev. 1.3

163

The ISOmodem has an internal analog-to-digital converter used to monitor the loop voltage when on-hook and
loop current when off-hook to check for parallel devices going off-hook. The host measures loop voltage or current
by reading U79 [4:0] (LVCS). To set the ISOmodem to monitor loop voltage in the on-hook state, the host issues
the following commands:

To set the ISOmodem to monitor loop current, the host issues the following commands:

Table 102. Intrusion Detection

Register

Bit(s)

Name

Function

U70

10

PPDM

Parallel Phone Detect
Mask

U70

2

PPD

Parallel Phone Detect

U76

15:9

OHSR

Off-Hook Sample Rate

U76

8

FACL

Force ACL

U76

7:5

DCL

Differential Current
Level

U76

4:0

ACL

Absolute Current Level

U77

15:12

IST

Intrusion Settling Time

U77

11

HOI

Hang-Up On Intrusion

U78

15:14

IB

Intrusion Blocking

U78

7:0

IS

Intrusion Suspend

U79

4:0

LVCS

Line Voltage/Current
Sense

U83

15:0

NOLN

No Line Threshold %V1

U84

15:0

LIUS

Line-in-use Threshold
%V1

U85

15:0

NLIU

Line-in-use/No Line
Threshold %V2

Command

Function

AT:R79

Host reads the loop voltage
from the LVCS Register U79
bits 4:0 while the modem is
on-hook.

Command

Function

ATH1

To go off-hook

AT:R79

Host reads loop current from
the LVCS Register U79 bits
4:0 while the modem is off-
hook.

Advertising