The ISOmodem has an internal analog-to-digital converter used to monitor the loop voltage when on-hook and
loop current when off-hook to check for parallel devices going off-hook. The host measures loop voltage or current
by reading U79 [4:0] (LVCS). To set the ISOmodem to monitor loop voltage in the on-hook state, the host issues
the following commands:
To set the ISOmodem to monitor loop current, the host issues the following commands:
Table 102. Intrusion Detection
Register
Bit(s)
Name
Function
U70
10
PPDM
Parallel Phone Detect
Mask
U70
2
PPD
Parallel Phone Detect
U76
15:9
OHSR
Off-Hook Sample Rate
U76
8
FACL
Force ACL
U76
7:5
DCL
Differential Current
Level
U76
4:0
ACL
Absolute Current Level
U77
15:12
IST
Intrusion Settling Time
U77
11
HOI
Hang-Up On Intrusion
U78
15:14
IB
Intrusion Blocking
U78
7:0
IS
Intrusion Suspend
U79
4:0
LVCS
Line Voltage/Current
Sense
U83
15:0
NOLN
No Line Threshold %V1
U84
15:0
LIUS
Line-in-use Threshold
%V1
U85
15:0
NLIU
Line-in-use/No Line
Threshold %V2
Command
Function
AT:R79
Host reads the loop voltage
from the LVCS Register U79
bits 4:0 while the modem is
on-hook.
Command
Function
ATH1
To go off-hook
AT:R79
Host reads loop current from
the LVCS Register U79 bits
4:0 while the modem is off-
hook.