Table 129. TAM Handset Record OGM

Host to Modem Commands / Data

Modem to

Host Result

Codes/Data

Local Modem Actions

AT:U199|A

OK

Mute the microphone and speaker paths to
the codec.

AT:U72,0110

OK

Configure Si3000 Register 1:
Enable speaker driver
Disable line output driver
Disable telephone instrument driver
Enable MBIAS output

AT:U72,05B3

OK

Configure Si3000 Register 5:
10 dB Line In gain
Mute Line In
20 dB MIC input gain
Enable MIC input
Mute telephone instrument input
Enable IIR filter

AT:U72,065C

OK

Configure Si3000 Register 6:
0 dB RX PGA gain
Disable Line Out
Disable telephone instrument output

AT:U72,075E

OK

Configure Si3000 Register 7:
0 dB RX PGA gain
Enable SPKRL
Mute SPKRR

AT:U72,0900

OK

Configure Si3000 Register 9:
0 dB Line Out attenuation
0 dB Speaker output attenuation

AT+VGR=128

OK

Set the Si3000-to-RS232 receive gain
(UC0) for TAM Hands-Free.

AT:U0B1,0500

OK

Restore Si3000-to-DAA transmit gain path
to allow voice samples to reach FDV block
for silence detection. This allows the driver
to automatically end OGM recording.

AT+VSD = 129

OK

Set sensitivity level for OGM recording
silence detection.

AT+VSM = 4

OK

Select G.711U

-law PCM, 8-bit, 64 kbps

format. The voice driver will need to track
the OGM format with the OGM PCM file.

AT+VTS = [1000,0,100]

OK

Play user record tone prompt.

AT:U199|8

OK

Mute speaker.

AT:U199&FFFD

OK

Enable microphone for OGM recording.

Advertising