An93 – Silicon Laboratories SI2493/57/34/15/04 User Manual

Page 25

Advertising
background image

AN93

Rev. 1.3

25

2.2.4.1. Hardware Interface Register 0

Hardware Interface Register 0 (HIR0) is the eight-bit wide read/write location where modem data and commands
are exchanged with the host. Writing a byte to the HIR0 adds that byte to the modem’s transmit FIFO (AT
command buffer in command mode or data transmission in data mode). If data are available (modem data in data
mode or command responses, such as OK, in command mode), reading from the HIR0 fetches data from the
modem’s receive FIFO. The maximum burst data rate is approximately 350 kbps (45 kBps).

2.2.4.2. Hardware Interface Register 1

Hardware Interface Register 1 (HIR1) contains various status and control flags for use by the host to perform data
flow control, to escape to command mode and to query various interrupt conditions. The HIR1 bit map is described
in Table 22. This register is reset to 0x63.

Bit 7 (RXF) is a read/write bit that gives the status of the 12-byte deep receive FIFO. If RXF = 0, the receive FIFO
contains less than 10 bytes. If RXF = 1, the receive FIFO contains more than 9 bytes and is full or almost full.
Writing RXF = 0 clears the interrupt.

Table 21. Hardware Interface Register Bit Map

A0

RD

WR

Action

Register

D7

D6

D5

D4

D3

D2

D1

D0

0

0

1

Read

HIR0

Modem data or command from receive FIFO

0

1

0

Write

Modem data or command to transmit FIFO

1

0

1

Read

HIR1

RXF

TXE

REM

INTM

INT

ESC

RTS

CTS

1

1

0

Write

RXF

TXE

*Note

INTM

*Note

ESC

RTS

n/a

*Note: REM and INT are read-only bits.

Table 22. Hardware Interface Register 1

Bit

Name

R/W

Reset

Function

7

RXF

R/W

0

Receive FIFO Almost Full

6

TXE

R/W

1

Transmit FIFO Almost Empty

5

REM

R

1

Receive FIFO Empty

4

INTM

R/W

0

Interrupt Mask

0 = INT pin triggered on rising edge of RXF or TXE only
1 = INT pin triggered on rising edge of RXF, TXE or INT (bit 3 below)

3

INT

R

0

Interrupt

0 = No interrupt
1 = Interrupt triggered

2

ESC

R/W

0

Escape

1

RTS

R/W

1

Request-to-Send (active low) — Deprecated — for flow control, use the
TXE and REM bits for polling- or interrupt-based communication.

This bit must be written to zero.

0

CTS

R

1

Clear-to-Send (active low) — Deprecated — for flow control, use the TXE
and REM bits for polling- or interrupt-based communication.

Advertising