A n 9 3 – Silicon Laboratories SI2493/57/34/15/04 User Manual

Page 100

Advertising
background image

A N 9 3

100

Rev. 1.3

Example: The United States specifies a busy tone “on” time from 450 to 550 ms and “off” time from 450 to 550 ms.
Thus the minimum “on” and “off” times are 0.45 s each , and the maximum “on” and “off” times are 0.55 s each.

The busy cadence minimum on time is 0.45 s, thus BMOT = 0.45 x 7200 = 0x0CA8.

The busy cadence minimum total time is 0.45 s + 0.45 s = 0.9 s, thus BMTT = 0.9 x 7200 = 6480 = 0x1950.

The maximum total time is 0.55 s + 0.55 s = 1.1 s, thus BDLT = (1.1 – 0.9) x 7200 = 1440 = 0x05A0.

The hexadecimal values are stored in the appropriate registers using the AT:Uhh command. Detection parameters
can be wider than the minimum specifications. This is often done in the modem defaults and other suggested
settings so that one set of parameters can cover a broad number of different country requirements.

Figure 26. Cadence Timing

K

0x0005

400/440

A0

0x0020

0x0200

0x0400

0x0040

B1

0x7448

0x7802

0x73D5

0x75A7

B2

0xC0F6

0xC0CB

0xC2A4

0xC26B

A2

0x4000

0x4000

0x4000

0x4000

A1

0x96AB

0x8359

0x8D93

0x85C1

K

0x0008

Table 50. BPF Biquad Values (Continued)

BPF Biquad

Values

Stage 1

Stage 2

Stage 3

Stage 4

Output Scalar

Maximum Cadence

TOTAL Time

Minimum Cadence

TOTAL Time

(BMTT)

(RMTT)

Cadence Delta

Time (BDLT)

(RDLT)

Minimum ON Time

(BMOT)

(RMOT)