C setting the alarm-set, Remote setup – Sanyo DSR-2108 User Manual

Page 75

Advertising
background image

Remote Setup

68

To set the alarm input/output conditions of the alarm input/output terminals.

b Alarm Out

Sets whether to output or not alarm signal from this unit.

• ON: Output enabled

• OFF: Output disabled

b Setting an alarm output terminal

Specify an alarm output terminal number (1 - 4) and set the
alarm output conditions.

1 Alarm Out No.

Specifies the alarm output terminal number (1 - 4).

2 Alarm In

Outputs an alarm signal when the specified external alarm
input terminal receives an input.

Input terminal number

DSR-2116: 1 -16, DSR-2108: 1 - 8

3 Motion ON

Outputs an alarm signal when the specified video input
terminal receives a motion detection signal.

Input terminal number

DSR-2116: 1 -16, DSR-2108: 1 - 8

4 Video Loss On

Outputs an alarm signal when a video loss occurs in the
specified video input terminal.

Input terminal number

DSR-2116: 1 -16, DSR-2108: 1 - 8

5 HDD Error

Sets whether to output or not an alarm signal when a hard
disk error occurs.

• ON: Alarm signal output enabled

• OFF: Alarm signal output disabled

6 Alarm Duration

Sets the duration of the alarm output signal.
(3 - 255 SECONDS)

b Setting an alarm input terminal

Specify an alarm input terminal number and set the type.

1 Alarm In No.

Specifies the alarm input terminal number.

Input terminal number

DSR-2116: 1 -16, DSR-2108: 1 - 8

2 Type

Sets the signal polarity of the specified alarm input
terminal.

• ----: Alarm input detection disabled

• N/O (Normal Open):

Normally open, detects input when closed

• N/C (Normal Close):

Normally closed, detects input when opened

C

Setting the Alarm-Set

1
2
3
4
5
6

1
2

L8HBT_WA(DSR-2116_2108)(GB).book 68 ページ 2009年5月27日 水曜日 午後4時50分

Advertising