Remote Setup

70

To set the recording conditions.

b Resolution (Common to all channels)

Sets the resolution for the recordings.

The set value applies to all channels.

b Channel-specific settings

These settings apply to the specified channel only.

1 Channel designation

Channel
DSR-2116: 1 -16, DSR-2108: 1 - 8

2 Frame Rate

Sets the recording rate.
(OFF, NTSC: 1 - 30 ips/PAL: 1 - 25 ips)

3 Quality

Sets the image quality in 5 levels (NETWORK/ECONOMY/
BASIC/NORMAL/FINE).

4 Recording

Sets the recording mode.

• DISABLE: Recording disabled.
• CONTINUOUS: Recording is performed while the DVR

is on.

• BY MOTION:

Recording is performed when the motion sensor built
into this unit detects a movement.

• BY EXT. SENSOR:

Recording is performed when a sensor connected to an
external alarm input terminal (ALARM IN) of this unit
reacts.

• BY SCHEDULE:

Recording is performed at the time slots specified in the
schedule.

5 Timer Set

Sets the schedule for SCHEDULE recording using the
[Schedule] screen. (Refer to P71 for information about the
setting procedure)

6 Motion Sensitivity

Sets the level of detection sensitivity (1 - 9) of the motion
sensor.
The lower the value, the higher the detection sensitivity.

7 Motion Zone

Sets the zone where the motion sensor is active.
A detection frame needs to be set when "PARTIAL ZONE"
is selected. (Refer to P71 for information about the setting
procedure)

• FULL ZONE: The motion sensor is active on the whole

screen.

• PARTIAL ZONE: The motion sensor is active in a set

detection frame.

8 Alarm Recording

ALARM recording is performed when an external alarm
signal is input to the specified external alarm input terminal
Input terminal
DSR-2116: -----, 1 -16
DSR-2108: -----, 1 - 8

9 Pre Record

Sets whether to perform or not pre-ALARM recording.
When enabled, recording is started approximately
5 seconds before the internal motion sensor or the
external sensor detector is triggered.

• ON: Pre-ALARM recording enabled
• OFF: Pre-ALARM recording disabled

F Post Event Record

Sets the duration of the ALARM recording
(2 - 30 SECONDS, 1 - 5 MINUTES, 10 MINUTES,
15 MINUTES).

G Audio

Sets whether to perform or not audio recording.

• ON: Recording of audio of live video enabled
• OFF: Recording of audio disabled

H Real Time Frame Rate

Sets the recording rate.
(OFF, NTSC: 1 - 30 ips/PAL: 1 - 25 ips)

I Quality

Sets the image quality for real-time recording in 5 levels
(NETWORK/ECONOMY/BASIC/NORMAL/FINE).

J Post Event Record

Sets the duration of the real-time recording (--, 2 - 30
SECONDS, 1 - 5 MINUTES, 10 MINUTES, 15 MINUTES)

Memo: If "--" is selected, recording is triggered when the

Record/Stop button is pressed or whenever an alarm
input occurs.

K Alarm Recording

Sets the alarm input terminal number that triggers
real-time recording.
Input terminal
DSR-2116: -----, 1 -16
DSR-2108: -----, 1 - 8

E

Setting the Record

• QUAD

• FULL

• HALF

1

2
4
6
7
8
9
F
G

H
J
K

I

5 3

L8HBT_WA(DSR-2116_2108)(GB).book 70 ページ 2009年5月27日 水曜日 午後4時50分