F100 PI – PING

Use function F100 PI to ping a remote host to see if it is reachable. If no IP Address is provided, F100 PI
uses the XL-GPS’s own IP Address, and tests whether the XL-GPS’s network port has a good network
connection.

To ping a known host, enter:

F100 PI<S><IP Address><CR>

For example:

F100 PI 206.254.000.021<CR>

The unit responds (example):

PING 206.254.000.021: REMOTE HOST FOUND.<CR><LF>

or

PING 206.254.000.021 : REMOTE HOST NOT FOUND.<CR><LF>

To test if the XL-GPS’s network port has a good connection, enter the following using in a serial port
session:

>f100 PI<CR>

XL-GPS responds:

PING : REMOTE HOST FOUND.<CR><LF>

or it responds:

PING : REMOTE HOST NOT FOUND.<CR><LF>

F100 PN – Change User Name

Use function F100 PN to change a user name. In a network port session, F100 PN changes the name of
the user you logged in as; operator or guest. In a serial port session, F100 PN changes the name of the
operator

user.

See “Command Line Interface” on page 29.

To change the user name, enter:

F100<S>PN<CR>