For example, enter, Xl-gps responds using the following format, F113<cr – Symmetricom XL-GPS User Manual

Page 112: F113 disable<cr><lf, F113 disable<cr, Ok<cr><lf, F113<s>show<cr

Advertising
background image

102

997-01530-01, Rev. C-25, Jan 2008

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

1

For example, enter:

F113<CR>

The XL-GPS displays the current configuration (example):

F113 DISABLE<CR><LF>

Or

F113 FREQ MEAS 1MHZ 50 000001<CR><LF>

To set the J3 Input Configuration, enter a character string using the same formats as the preceding
XL-GPS responses

. Only valid values are accepted.

To disable F113, enter:

F113 DISABLE<CR>

Or, to enable Freq Meas of a 1 MHz input with a 50

Ω input impedance every 1 seconds, enter:

F113 FREQ MEAS 1MHZ 50 1<CR>

To all three of the above examples, XL-GPS responds:

OK<CR><LF>

If enabling Freq Meas, display the Freq Meas measurements using the following format:

F113<S>SHOW<CR>

XL-GPS responds using the following format:

Interval<S>is<S><INT><S>seconds<CR><LF>

+#.######e-##<CR><LF>

FREQ MEAS

= ASCII character string "FREQ MEAS" to set J3 to make frequency measurements

<S>

= ASCII space character one or more.

<FREQ>

= FREQ MEAS Input Frequency: 1MHZ, 5MHZ, 10MHZ

<IMP>

= Input Impedance: 1K or 50

<INT>

= Frequency Measurement Interval. This is the gate time of the measurement. Range: [000001,

999999] in seconds.

<CR><LF>

= line terminator, either a carriage return and line feed for output strings or a carriage return only for

input strings.

F

= ASCII character F.

Advertising