Or 10, Pulse period with 5, Pulse width), enter – Symmetricom XL-GPS User Manual

Page 109: Xl-gps responds, And the stop time or falling-edge at 55, Or 100, Pulse period with 50, Ok<cr><lf

Advertising
background image

997-01530-01, Rev. C-25, Jan 2008

99

2

5

1

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

For example, to produce a repetitive 5 microsecond pulse occurring every 10 microseconds (i.e.,
repetitive pulses with 100 kPPS frequency with the start time or rising-edge on-time and the stop time or
falling-edge at 5

μS

- or 10

μS

pulse period with 5

μS

pulse width), enter:

F111 PPO XXX:XX:XX:XX.XXXXX0 XXX:XX:XX:XX.XXXXX5<CR>

XL-GPS responds:

OK<CR><LF>

Or, for example, to produce a repetitive 50-microsecond pulse occurring every 100 microseconds (i.e.,
repetitive pulses with 10 kPPS frequency with the start time or rising-edge at 5

μS

and the stop time or

falling-edge at 55

μS

- or 100

μS

pulse period with 50

μS

pulse width), enter:

F111 PPO XXX:XX:XX:XX.XXXX05 XXX:XX:XX:XX.XXXX55<CR>

XL-GPS responds:

OK<CR><LF>

Or, for example, to produce a repetitive 50-microsecond pulse occurring every 100 milliseconds (i.e.,
repetitive pulses with 10 PPS frequency with the start time or rising-edge at 5

μS

and the stop time or

falling-edge at 55

μS

- or 100ms pulse period with 50

μS

pulse width), enter:

F111 PPO XXX:XX:XX:XX.X00005 XXX:XX:XX:XX.X00055<CR>

XL-GPS responds:

OK<CR><LF>

Or, for example, to produce a repetitive one-minute pulse occurring every hour, enter:

F111 PPO XXX:XX:10:00.000000 XXX:XX:11:00.000000<CR>

XL-GPS responds:

OK<CR><LF>

Clock Reading

Pulse

001:00:00:00.000000 Start

001:00:00:00.000001 No Change

001:00:00:01.000000 Stop

001:01:00:00.000000 No Change

001:00:00:00.000000 Start (etc...)