ATV58 TRX TYPE H SPECIFICATIONS

Environmental Specifications

Enclosure type

ATV58HU09M2 to U90N4: IP20/open type controllers according to Standard
EN50178.
ATV58HU90M2 to D46M2, ATV58HD12N4 to D79N4: UL Type 1 with conduit
connection kit (see page 131 for list of conduit entry kits).
ATV58HC10N4X to C33N4X: IP20 on all surfaces except the bottom. IP00
on the bottom due to the power connections.

Resistance to vibrations

According to IEC 60068-2-6:
1.5 mm zero to peak from 3 to 13 Hz
1 gn from 13 to 200 Hz
ATV58HC10N4X–C33N4X:
0.6 gn from 10 to 55 Hz

Resistance to shocks

According to IEC 60068-2-27: 15 g, 11 ms

Ambient pollution degree

ATV58HU09M2–D12M2 and ATV58HU18N4–D23N4:
Pollution degree 2 conforming to IEC 60664-1, EN50718, and NEMA ICS-1.
ATV58HD16M2–D46M2 and ATV58HD28N4–D79N4: Pollution degree 3
conforming to IEC 60664-1, EN50718, and NEMA ICS-1.
ATV58HC10N4X–C33N4X: Pollution degree 2 conforming to
IEC 60664-1, EN 50718, and NEMA ICS-1.
Protect the drive controller against dust, corrosive gas, and falling liquid.

Maximum relative humidity

95% maximum, non-condensing and without dripping according to IEC
60068-2-3. Provide a heating system if there is

condensation.

Maximum ambient
temperature

Storage: -25 to +65 °C (-13 to +149 °F)
Operation:
Drive controllers ATV58HU09M2–U72M2 and ATV58HU18N4–U90N4:

[1]

-10 to +50 °C (+14 to 122 °F) without derating
-10 to +60 °C (+14 to 140 °F) with fan kit

[2]

and derating of the current 2.2%

per °C above 50 °C
Drive controllers ATV58HU90M2–D46M2 and ATV58HD12N4–D79N4:
-10 to +40 °C (+14 to 104 °F) without derating
-10 to +50 °C (+14 to 122 °F) with fan kit

[2]

and derating of the current 2.2%

per °C above 40 °C
Drive controllers ATV58HC10N4X–C33N4X:
-10 to +40 °C (+14 to 104 °F) without derating
-10 to +50 °C (+14 to 122 °F) with derating of the current 2.2%
per °C above 40 °C

Altitude

3300 ft (1000 m) maximum without derating; derate the output current by 1%
for each additional 330 ft (100 m)

Operating position

Vertical, ±10°, with power terminals at the bottom

[1]

ATV58HU54N4X, ATV58HU72N4X, and ATV58HU90N4X can be used at their highest VT rating in a
40 °C maximum ambient temperature.

[2]

See page 130 for list of fan kits.