Class

Type Number

Modifications

8839

58M

Product

Code

Enclosed Drive

58M

Altivar

®

58 TRX

Horsepower

Code

HP rating @
208 V, 230 V
or 460 V

Code

HP rating
@ 460 V

C

1 hp

Q

60 hp

D

2 hp

R

75 hp

E

3 hp

S

100 hp

F

5 hp

T

125 hp

G

7.5 hp

U

150 hp

H

10 hp

W

200 hp

J

15 hp

X

250 hp

K

20 hp

Y

300 hp

L

25 hp

Z

350 hp

M

30 hp

4

400 hp

N

40 hp

5

450 hp

P

50 hp

6

500 hp

Enclosure Type

Code

Environment rating

G

Type 1

A

Type 12

B

Type 1G Filtered
(125–500 hp only)

Voltage Rating

Code

Utilization/
Distribution

2

200/208 Vac

3

230/240 Vac

4

460/480 Vac

Power Circuit Description

Code

Circuit Type

W

Drive controller only

Y

Drive with bypass

Application Type

Code

Applied rating

C

Constant Torque

V

Variable Torque

Standard Features

• Circuit Breaker Disconnect

• UL508C listing with NEMA 1CS 7.1 compliance

• 65,000 AIC short circuit rating (1–100 hp) or

100,000 AIC short circuit rating (125–500 hp).

• Industrial vault style disconnect handle with

lockout /tag-out provisions

• HAND-OFF-AUTO selector switch and manual

speed spot

• Door-mounted keypad display

• Auto Start Relay (115-volt control)

• One Form C AFC Run mode contact

• One Form C AFC Fault contact

• Remote fault condition reset in AUTO mode

with transition of auto start contact

• Manual fault condition reset in OFF position of

H-O-A selector switch

• Safety interlock/Run permissive location wired

to customer terminal strip

• Permanent Wire Markings

• White Component mounting Plate

• Conduit knockouts on top and bottom for wall

mounted enclosures

• Removable conduit entry plates on top and

bottom for floor mount enclosures

• ANSI 49 gray enclosure

• As-built wiring diagrams

Bypass Standard Features

• Class 20 Overload Protection with door-

mounted reset

• AFC-OFF-BYPASS selector switch

• TEST-NORMAL selector switch

• Isolation and Bypass Contactors (with

mechanical and electrical interlocking)

• Bypass and isolation contactor sequencing

provides true motor isolation

• Remote automatic bypass operation using

Auto Start Relay

• As-built wiring diagrams